Page 1
MULTI-PURPOSE DIGITAL ACCESS CONTROL KEYPAD Programming & Installation Manual FOR ELECTRIC LOCK, INTER-LOCK AND SECURITY SYSTEM INSTALLATIONS...
INTRODUCTION Output 1 Output 2 3 Amp Solid State 1 Amp Relay DESCRIPTION OF CONNECTION TERMINALS & INDICATORS AMBER GREEN...
Page 4
CONNECTION TERMINALS 1 - 2 : TAMPER N.C. 3 - 4 : 12V DC -- 6 - 7 : OUTPUT 1 -- Fail-Secure Electric Lock in Default 8 - EG IN -- 9 - 10 - 11 : OUTPUT 2 12 : KEY ACT -- 13 : DU OUT -- 14 : GND (-) --...
Page 5
15 : DOOR SENS -- NOTE: 1) Door Auto Re-lock 2) Door Forced Open Warning 3) Door Propped-up Warning 4) Inter-lock Control 16 : O/P 1 INHIB. -- 17 : INT. LOCK...
Page 6
THE LED INDICATORS MAINS (AMBER) DOOR / INHIBIT (GREEN / RED) OUTPUT 2 (GREEN) BACK LIGHTING (Back-lit Version Keypad Only) THE PACIFIER TONES & THE LED INDICATING SIGNALS STATUS TONES* LED SIGNALS 1. In programming mode 2. Successful key entry 1 Beep 1 Flash 2 Beeps...
STANDARD PROGRAMMING SUMMARY CHART A) Enter Programming Mode with Master Code (Exit-Factory Master Code: 0 0 0 0) NOTE: B) System Refreshing – C) Code Entries – 1) Recording Master Code and User Codes – (No Default Codes) 2) Recording Super User Code – (No Default Codes) 3) Recording Duress Codes –...
Page 8
(Default: Momentary, 1-second for all 3 outputs) (default=1 second) (default = 1 second) (Default: Fail-Secure) (Default: 10 tries / 30 seconds) (default) G) Door Forced-Open Warning – (Default: Disabled) (default) (Default: 1 long beep) (default)
Page 9
I) User Code Entry Modes (Auto or Manual) – (Default: Manual) (default) (Default: ON) (default) K) Main LED Flashing ON-OFF – (Default: Flashing) (default) L) Egress Delay & Warning – (Default: Instant, No warning) (default) M) Delay Time to Start Door Propped-up Warning – (Default: OFF) (default) N) Exit Programming Mode...
SETTING & PROGRAMMING Criteria for Programming MUST DO NOT Enter and Exit Programming Mode key. Master Code 3. Exit the programming mode by pressing the NOTE:...
Page 11
New Master Code NOTE: Programming Example : 0 0 0 0 2. Program a new Master Code 3 2 8 9 for the keypad: NOTE: 3 2 8 9 System Refresh (Complete Data Refresh) (Refresh Code 8901) 3 2 8 9 key to clear all the current stored data except the Master Code: NOTE:...
Page 12
User ID Entry of Code Output 1 Output 2 NOTE: 00-99 Programming Example : 3 2 8 9 2. Program an User Code 8 3 2 1 for output 1 ---------- One of the 100 user codes (user ID: 00-99, taking ID = 01 as example): 3.
Page 13
Super User Code NOTE: Programming Example : 3 2 8 9 2. Program 2 5 8 0 as Super User Code:...
Page 14
NOTE: This feature is recommended for Fail-safe locks only. REMARK : NOTE:...
Page 15
User ID Duress Code NOTE: For example: 1 3 5 7 3 3 5 7 1 3 5 8 Programming Example : 3 2 8 9 2. Program 3 3 5 7 as 1st Duress Code: Program 2 3 9 8 0 as 2nd Duress Code --- if more user needs duress code: NOTE :...
Page 16
One-Time Time-Limit User ID Entry of Code NOTE: Programming Example : 3 2 8 9 2. Program a Visitor Code 1 3 7 8 at ID “0” for One-Time use: 3. Program a Visitor Code 2 3 0 8 9 at ID “1” with Time-Limit of 5 hours: 4.
Page 26
SET KEYPAD TO SINGLE USER MODE (to whom it may require) Important Notes: “Single-User Mode” Programming Summary Chart for “Single-User Mode” A) Enter Programming Mode with Master Code (Exit-Factory Master Code: 0 0 0 0) NOTE: B) System Refreshing to Single User Mode – (Default: 8 9 0 0, Single-user mode) C) Code Entries –...
Page 27
2) Recording Super User Code – (No Default Codes) 3) Recording Duress Codes – (No Default Codes) 4) Recording the Visitor Codes – (No Default Codes) Programming Examples for “Single-User Mode” 0 0 0 0 8 9 0 0 3 2 8 9 8 3 2 1 output 1 5 4 3 2...
SPECIFICATIONS Input Sensing Terminals: Output Contacts: Tamper Switch Contact: Auto Refreshing Time During Code Entry: Ambient Humidity: Dimensions: Weight: Specifications are subject to change for modification without notice...
APPLICATION EXAMPLES 1) BASIC WIRINGS OF A STAND ALONE DOOR LOCK TAMPER ( + ) ( – ) ( + ) ( – ) (–) DOOR 12V DC DOOR LOCK SENS N.C. N.C. 12V DC DOOR SENS SWITCH POWER (OPTIONAL) SUPPLY ELECTRIC LOCK EGRESS BUTTON...
Page 30
2) BASIC WIRINGS FOR DOOR LOCK OPEN AND ALARM ARM-DISARM CONTROL TAMPER (–) (–) N.C. 12 VDC DOOR 12V DC POWER SUPPLY ELECTRIC LOCK EGRESS BUTTON N.O. 1N4004 (INSIDE THE HOUSE) OUTPUT 2 ( – ) DOOR O/P 1 INT. N.C.
Page 31
3) BASIC WIRINGS OF AN INTER-LOCK SYSTEM USING TWO KEYPADS CROSS WIRE CONNECTION FOR INTER-LOCK FUNCTIONS CROSS WIRE CONNECTION FOR INTER-LOCK FUNCTIONS COMMON GROUND N.C. N.C. DOOR 2 DOOR 1 SENSING SENSING TAMPER (–) (–) TAMPER (–) (–) N.C. 12 VDC DOOR N.C.
APPLICATION HINTS FOR THE AUXILIARY FACILITIES (A) TAMPER N.C. The tamper switch is Normally Closed while the keypad ALARM CONTROL PANEL is secured on gang box. It is open when the keypad is TAMPER removed from the gang box. To prevent sabotage, N.C.
Page 33
+12V 1.5K LOW POWER 24 HOUR N.O. PIEZO BUZZER PROTECTION ZONE TO PROTECTION ZONE OF AN ALARM CONTROL PANEL N.C. N.C. MAGNETIC CONTACT Use the Normally Open (N.O.) output contact to shunt a Normally Closed (N.C.) protection zone of an alarm system. Set output contact to Start / Stop Mode (Programming Option 51).
AUXILIARY INFORMATION DRY CONTACT N.C. N.O. TRANSISTOR OPEN COLLECTOR OUTPUT OPEN COLLECTOR N.O. CONTACT OUTPUT ---- OUTPUT ---- EQUIVALENT Output switches to Output switches to ground when activated ground when activated...