Download Print this page

Mitsubishi Electric MI1002-W Startup Manual page 2

Hide thumbs Also See for MI1002-W:

Advertisement

MITSUBISHI ELECTRIC
INDUSTRIAL PC
MI1002-W,MI1002-W-CL
START-UP GUIDE (Back)
Be sure to read the "Safety Precautions" on the front page.
This page contains important information related to safety.
This guide descries the steps from opening the carton box until this product
is usable. Please set up this product according to the steps described in this
guide.
Step 1
Check the accessories.
Open the carton box, and then make sure you have all the accessories listed below:
AC adapter
Power cord (Only MI1002-W)
Power cord clamp
2-pin conversion plug (with ground wire) (Only MI1002-W)
FG cable
Getting Started (This guide)
End User License Agreement (Windows)
Open Source Software Licenses
Edgecros Basic Software License Agreement
SLMP Data Collector License Agreement and End User License Agreement
Keep the accessories in a safe place.
Place the product to a proper
Step 2
location.
Determine the location to place this product.
 The environment that satisfies the following conditions
Operating
Ambient temperature: 0℃ to 55℃
Humidity: 10% to 85 % (No condensation)
 AC 100V 3-pin outlet with ground electrode, or
AC 100V 2-pin outlet with ground terminal
Install this product near an outlet that can be easily reached.
 A place with minimal exposure to dust, moisture, direct sunlight, or rain
 A place where flammable gas or corrosive gas is not present
 A place where the product can be fixed securely in place or on a flat, sturdy board
The power cord supplied with this product is for use in Japan only. If
you need to connect to a power supply exceeding AC 125V or using in
areas other than Japan, you need to prepare a dedicated power cord.
Please prepare a power cord corresponding to the power supply of the
country or region where this product will be used, or consult your sales
representative.
If you are using a 2-pin outlet with ground terminal, use a 2-pin
conversion plug with a ground wire supplied with this product and
connect the ground wire securely to the ground terminal of the outlet.
Use of an outlet other than that specified causes fire and electrical
leakage.
Be sure to ground the FG cable. Otherwise, this product may not
perform sufficiently depending on the environment.
Component names and functions
● Front panel
● Rear panel
● LEDs on the top panel
1
POWER LED
The switch to turn this product on or off.
The light is blue when on, red when off.
2
Display connector (HDMI)
HDMI-compatible connector
3
USB connector (4 ports)
USB 2.0-compatible connectors. Can be used for connecting USB interface-
compatible devices.
4
LAN connector (2 ports)
Network connectors compatible with 1000BASE-T, 100BASE-TX, and
10BASE-T.
5
Power connector
Used to connect the AD adapter supplied with this product.
6
Serial port connector
Used to connect to products with RS-232C-compatible serial interfaces.
(RS-232C)
7
Serial port connector
Used to connect to products with RS-485-compatible serial interfaces.
(RS-485)
8
Functional grounding
Used to connect the FG cable (accessory).
screw
9
Link/Act LED
Indicates the access status of the LAN port.
(Link/Act)
While connecting to LAN: Lit in amber.
While transferring data:
Blinking in amber
10
SPEED LED
Indicates the communication speed of the LAN port.
While connecting to 1000Base-T:
While connecting to 100Base-T:
While connecting to 10Base-T:
11
SATA access LED
Blinking (in green) while accessing the internal storage.
12
PG0 LED
These LEDs can be set up by using an application.
Blinking (green), lit (green), or light off
13
PG1 LED
Step 3
Connect the cables to the connectors of this product.
When connecting
the connector, be
careful of its
orientation. (*2)
(*1) Attach the FG cable before connecting the power cord to an outlet by referring to the procedure
on how to attach the FG cable described later in "Hardware Quick Reference."
(*2) When attaching or removing the connector, firmly hold the part of the connector marked with an
arrow.
(*3) Attach the power cord retention bracket before connecting the power cord to an outlet by
referring to the procedure on how to attach the power cord retention bracket described later in
"Hardware Quick Reference."
(*4) If you are using a 2-pin outlet with ground terminal, use a 2-pin conversion plug with a ground
wire supplied with this product. Before attaching or removing a ground wire to/from the ground
terminal, be sure to unplug the power plug from the outlet.
Icon
Display device compatible with an HDMI interface
USB interface device (such as a hub)
1000BASE-T/100BASE-TX/10BASE-T interface device (such as a hub)
COM1
Device with a serial interface conforming to the RS-232C standard
COM2
RS-485
Device with a serial interface conforming to the RS-485 standard
FG cable (accessory)
Hardware Quick Reference
●FG cable
Attach the FG cable according to the procedure below.
(1) Remove the functional ground screws on the rear panel. Then, attach one end of the
FG cable to the rear panel and tighten the functional ground screws.
(2) Ground the other end of the FG cable.
 Be sure to ground the FG cable. Otherwise, this product may not demonstrate
sufficient performance depending on the environment.
 Be sure to ground the FG cable before connecting the power plug to an outlet.
To remove the grounded FG cable, be sure to turn the power to the product off
and unplug the power plug from the outlet in advance.
●Preventing the power cord from coming out of an outlet
(1) Pass the hook and loop fastener with the protrusions facing in through a rectangle
hole on one side of the plate.
Fold back the fastener to a length of around 100 mm and affix it.
Protrusions
(2) Insert the power cord cable into the notch in the plate.
Move the plate to the base of the power cord connector.
(3) Loop the fastener around the AC adapter.
Pass the fastener through the other rectangular hole on the plate.
Lit in green.
Lit in amber.
Lights off.
Connect cables
Connect the power
Then, connect the
cord to the AC
power cord to an
outlet. (*4)
adapter. (*3)
Device to connect
Cable
Notch
Step 4
Turn on this product.
Turn on the power to this product by pressing the POWER switch on the front panel.
(1) Press the POWER switch on the front panel.
(*1)
Product specifications
Item
Mitsubishi Electric Corporation Industrial PC MELIPC Series
Model number
MI1002-W
CPU
Intel
Number of processors
1
CPU core
Dual core
Cooling method
Heat sink (Fanless)
Memory
Type
DDR3L SDRAM
Capacity
4 GB
Error detection &
Non-ECC
correction
Operation clock
1066 MHz
Buffer function
None
Storage
Type
eMMC / mSATA SSD
Capacity
4 GB / 60 GB
Network (wired)
1000BASE-T/100BASE-TX/10BASE-T
(Compatible with AutoMDI/MDI-X)
Interfce
USB
USB 2.0 compliant (Type-A) x 4 (front panel)
LAN
RJ45 x 2 (front panel)
Display
HDMI (Type-A, 1.4a) x 1 (front panel)
Serial
RS-232C x 2 (rear panel) 2.5kV withstand voltage
RS-485 x 1 (rear panel) 2.5kV withstand voltage
Size
Width: 186 mm, Height: 26mm, Depth: 150 mm
Weight
0.90 kg (excluding the AC adapter) /
1.3 kg (including the AC adapter)
OS
Windows10 IoT Enterprise LTSB 2016 64bit
Power supply (AC adapter)
AC100 to 264V
Power consumption (Max.)
35 W
Temperature & humidity
Operating: 0℃ to 55℃ / 10% to 85% (No condensation)
Storage: -20℃ to 75℃ / 10% to 85% (No condensation)
*1 The power cord supplied with this product is compatible with AC 100V and available for use in Japan
only. Be sure to connect the power cord to a 100V outlet. When using this product in a country or region
other than Japan, prepare the power cord corresponding to the power supply of the country or region
where this product is used.
When using the MI1002-W-CL, prepare a power cable that conforms to the power supply to be used and
the safety standards of the use area.
(4) Pull the fastener so it is not slack. Fold back and affix the fastener.
(5) Check to make sure that the power cord is secured as shown in the figure.
●台灣有害物質限制使用管理辦法 (RoHS)
限用物質含有情況標示聲明書
Declaration of the Presence Condition of the Restricted Substances Marking
設備名稱:電腦(微型計算機)
Equipment name
限用物質及其化學符號 Restricted substances and its chemical symbols
單元
Unit
Lead
Mercury
Cadmium
(Pb)
(Hg)
(Cd)
電路板
外殼
RTC Battery
(鈕扣電池)
電源供應器
配件
(線材、端子等)
備考 1:「超出 0.1 %」及「超出 0.01 %」係指限用物質之百分比含量超出百分比含量基準值。
Note 1: "Exceeding 0.1 wt %" and "exceeding 0.01 wt %" indicate that the percentage content of the restricted
substance exceeds the reference percentage value of presence condition.
備考 2:「○」係指該項限用物質之百分比含量未超出百分比含量基準值。
Note 2: "○" indicates that the percentage content of the restricted substance does not exceed the percentage of
reference value of presence.
備考 3:「—」係指該項限用物質為排除項目。
Note 3: The "—" indicates that the restricted substance corresponds to the exemption.
TRADEMARKS
Microsoft, and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States
and/or other countries.
Intel, and Intel Atom are either registered trademarks or trademarks of Intel Corporation in the United States and/or other
countries.
The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered
trademarks of HDMI Licensing Administrator, Inc. in the United States and other countries.
The company names, system names and product names mentioned in this manual are either registered trademarks or
trademarks of their respective companies.
In some cases, trademark symbols such as '
TM
' or '®' are not specified in this manual.
This product was developed and manufactured by Mitsubishi Electric Corporation in collaboration with NEC Corporation.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14 , YADA-MINAMI 5-CHOME , HIGASHI-KU, NAGOYA , JAPAN
When exported from Japan, this manual does not require application to the
Ministry of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
© 2018 MITSUBISHI ELECTRIC CORPORATION
®
Atom
Processor E3826 (1.46GHz)
*1
, 50/60Hz±3Hz
型號(型式): EGW001-003
Type designation (Type)
六价铬
多溴联苯
多溴二苯醚
相對應排除
Hexavalent
Polybrominated
Polybrominated
項目依據
chromium
biphenyls
diphenyl ethers
(D1~D37)
(Cr(VI))
(PBB)
(PBDE)
D13,D14,D16
D13

Advertisement

loading

This manual is also suitable for:

Mi1002-w-cl