USING THE KEYPAD

The Lyric Smart Keypad can control the security functions of the Lyric Smart Controller. The keypad also has two menus for setting various
options (see Keypad Settings Menu below). Refer to the Lyric Smart Controller's User Guide for more information about Security functions.

Keypad System Functions

NOTE: Before entering any command, the keys must be lit (key lighting automatically turns off after a period of inactivity, if the Auto Off option
is enabled). If the keys are unlit, press any key before continuing.
FUNCTION
PRESS
Arm Away
Away then enter user code.
Arm Stay
Stay then enter user code.
Quick Arm
Hold Security Shield for 3
seconds, then select Away or
(if programmed)
Stay arming mode.
Bypass Zones
With system not ready:
(if zones are
Away or Stay then enter user
faulted)
code.
Press Select when prompted.
Panic
Hold Panic key for 3 seconds,
then select:
(if programmed)
• Fire
• Police (default = silent)
• Medical
Disarm
Security Shield, then enter user
code.
Cancel Silent
Security Shield, then enter user
Panic Alarm
code.
Display
Status
security status
Cancel
Cancel

Keypad Settings Menu

There are two Settings menus, one for users and one for the installer. Use the
Select, Scroll and Cancel keys to navigate the menus.
Key
Function
Press and hold to start the Settings menu.
Select [ 1 ]
Also used to select menu options.
Press to scroll through the available menus and the settings
Scroll [ 0 ]
in menus.
Cancel (Away)
Cancels the current entry and returns to Status display.
To Access User Settings
1.
Press and hold the Select [ 1 ] key until the menu begins.
2. Use the Scroll [0] key to scroll the settings.
3. Use the Select key to choose the desired menu item.
4. Use the Scroll key to toggle the menu options.
5. Press the Select key to choose an option.
6. Press the Select key again to save your settings.
User Settings Menu (brackets [ ] indicate default values; greater than
symbol ">" on keypad display indicates keypad's current setting)
Options
Setting
Chime
[On]/Off
Exit Tone
[On]/Off
(beeps)
Entry Tone
[On]/Off
(beeps)
Voice
[Med]/High/Off
Volume
Key Level
[Med]/High/Low
Display Level [Med]/High/Low
Always On/[Auto
Backlight
Off]/On Alarm
(for keys)
Only
Firmware Upgrades
Software upgrades may be available for this product. Upgrades can be
installed manually using the Lyric Smart Controller or can be done via
AlarmNet 360™.
To upgrade the keypad firmware using the Lyric Smart Controller, go
to the following Controller menu and follow the prompts:
Security > Tools > Installer Code > Advanced > Upgrade Sensor
Firmware
After performing the upgrade command, the keypad displays the
upgrade status then, when done, automatically resets twice. After the
keypad completes the reset, it returns to normal operation.
RF Exposure
Warning – The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8
inches (20 cm) from all persons and must not be co-located or operating in conjunction with any other antenna
or transmitter except in accordance with FCC multi-transmitter product procedures.
Mise en Garde
Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à une distance
de séparation d'au moins 7,8 pouces (20 cm) de toutes les personnes.
Ê800-19484V1vŠ
800-19484V1 11/15 Rev. B
NOTES
Exit delay begins. System arms in Away mode.
(see User Guide for Auto-Stay option, if enabled)
Exit delay begins. System arms in Stay mode.
Quick Arm allows arming the system without
entering a user code.
Exit delay begins. System arms in selected mode.
System automatically bypasses all faulted zones
and arms in the selected mode.
NOTE: Force Bypass must be enabled at the
controller for this feature to operate.
The 3 Panic keys light red until one is selected,
then:
• An alarm signal is sent to the central station
• Alarm sounding starts (if programmed to do so)
• If the selected Panic function is programmed to
be silent, the keypad returns to normal state.
System disarms.
Panic alarm is canceled.
Displays the system's current security status.
(Armed/Disarmed, Away/Stay/Custom arming
mode, exit countdown, Ready/Not Ready, Fault,
Trouble and Bypass conditions.)
Cancels the entry and returns to Status display.
Notes
On: keypad beeps when a zone is faulted if
Chime mode is turned on at the control
Off: keypad does not beep upon faulted zones
On: keypad beeps during exit delay period
Off: keypad does not beep during exit delay
On: keypad beeps during entry delay period
Off: keypad does not beep during entry delay
Adjusts the desired volume for keypad
announcements.
Off: mutes arm/disarm announcements;
alarms are always announced
Adjusts the brightness of key lighting.
Adjusts the brightness of the display.
Always On: display remains always on
Auto-Off:
display turns off after a period of
inactivity.
On Alarm
display turns on when an
Only:
alarm occurs and remains lit until
the keypad is disarmed.
Shield & Panic Indicators
The Security shield is a single key; the
not separate buttons. Security status is indicated by color:
Indicator
Color
Security
unlit
Shield
Green
Red
White
Status
Panic
unlit
Red
To Access Installer Settings
1.
Press and hold the [3] key until "Advanced Menu Use Scroll Key"
begins.
2. Use the Scroll [0] key to scroll the menus.
3. Use the Select key to choose the desired menu item.
4. Use the Scroll key to toggle the menu options.
5. Press the Select key to choose an option.
6. Press the Select key again to make settings or choose options.
Installer Settings Menu
Setting
Options
Firmware
App (version level)
Touch (touch screen)
Use Scroll to
Boot (boot loader)
choose firmware
RF6 (comm. protocol)
components
Default Keypad
Cancel/Delete
NOTE: After 24 hours,
the "Delete" function
is disabled. If selected
after 24 hours, "Must
use panel to delete" is
displayed. If keypad
removal is needed, the
keypad must be
deleted from the
associated controller
using the controller's
programming options.
Reset Keypad
Cancel/Select
FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation
Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the
equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the
following statement for your information: This equipment generates and uses radio frequency energy and if not
installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause
interference to radio and television reception. It has been type tested and found to comply with the limits for a
Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to
provide reasonable protection against such interference in a residential installation. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different
branch circuits.
• Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA CLASS B STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS-210 of Industry Canada. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries Canada. Son
fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d'interférences nuisibles.
(2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une reception
indésirable.
and
icons are
State
Meaning
• System disarmed, not ready to arm,
unlit
(press Status key to show faults)
• Zone fault or zone trouble
system ready to arm
lit steady
• System Ready with AC Loss
blinking
System armed
lit steady
• Exit delay in progress system
blinking
arming,
• System Armed with AC Loss
• Entry delay with AC Loss
AC Loss (check Shield for system
blinking
status)
Not active.
unlit
Active, waiting for selection of panic
lit steady
alarm type. Also indicates AC Loss if
Status is blinking.
Notes
Displays the various keypad
component firmware versions.
See Firmware Upgrades section for
details on upgrading the firmware.
Delete: if used within 24 hours of
initial enrollment, allows keypad
reenrollment in a specific controller
in case enrollment in that controller
failed (i.e., the keypad inadvertently
enrolled in a different controller).
"Delete" resets the keypad to
factory default settings and
removes the communication link
data in the controller in which it is
enrolled, allowing the keypad to be
reenrolled in the desired controller.
Cancel: exits from Default Keypad
screen without making a change.
Use to manually reset the keypad.
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright  2015 Honeywell International Inc.
www.honeywell.com/security

Advertisement

loading

This manual is also suitable for:

Lyric lkp500-enc