Wabtec Microphor LF-210 Installation & Service Manual

Microflush half gallon toilets air operated
Hide thumbs Also See for Microphor LF-210:

Advertisement

Quick Links

Microflush Half Gallon Toilets
Model LF-210
Air Operated
Installation/ Service Manual
P/ N 24154
452 East Hill Road
Willits, CA 95490 USA
Phone: 707.459.5563
Toll Free: 1.800.358.8280
Fax: 707.459.6617
E-mail: info@microphor.com
www.microphor.com
www.wabtec.com
24154.WPD
10/16/01

Advertisement

Table of Contents
loading

Summary of Contents for Wabtec Microphor LF-210

  • Page 1 Microflush Half Gallon Toilets Model LF-210 Air Operated Installation/ Service Manual P/ N 24154 452 East Hill Road Fax: 707.459.6617 Willits, CA 95490 USA E-mail: info@microphor.com Phone: 707.459.5563 www.microphor.com 10/16/01 Toll Free: 1.800.358.8280 www.wabtec.com 24154.WPD...
  • Page 2: Rough-In Dimensions

    ROUGH-IN DIMENSIONS Cut out at rear of toilet. Run 1/4" compressed airline through finished wall or floor within inside perimeter of toilet. NOTE: Toilet is designed for flush installation to finished wall. Below are rough-in dimensions and may vary ½" (plus or minus). These measurements are subject to change or modification. No responsibility is assumed for use of superseded or voided installation information.
  • Page 3: Customer Service

    THANK YOU! CAUTIONS Thank you for purchasing a Microphor product. Water Pressure to the toilet must be regulated at Please read this manual completely prior to an even pressure between 20 to 50 PSI. installation of your Microflush® toilet. Microphor Air Pressure at the toilet must be regulated at 60-65 General Terms and Conditions Covering Sales PSI constant.
  • Page 4: Installation Procedure

    AIR SYSTEM DESIGN AIR CONNECTION Filter-regulators are Install a filter-regulator available in a variety of assembly in airline. Place sizes and types. Their the filter-regulator as close purpose is to remove as possible to the first water, oil and other toilet and in an accessible foreign matter from the air location.
  • Page 5: Drain Connection

    6. Assemble the Air Connecting Kit (P/N 93086) DRAIN CONNECTION provided and connect to incoming air supply. - See Rough-In Dimensions Do not connect to flush Activator. Bottom Discharge Models: Center on floor flange 7. Turn OFF air shut-off cock at toilet. 12"...
  • Page 6: Routine Maintenance

    Pipe will protect flapper seal. If valve will not ROUTINE MAINTENANCE operate with water off, hold flush lever down and Your Microflush toilet turn water on and off quickly to free valve action. USAGE LUBRICATE has an air-operated Light Every 5 years When the passage becomes clear, turn on the water Air/Water Sequence Medium Every 2-3 years...
  • Page 7: Troubleshooting

    TROUBLESHOOTING Your Microflush ® toilet is designed to give you years of trouble-free operation. Please check the following before beginning any service or repair: Water supply: 1 Is the water turned on? Is the water pressure between 20 and 50 psi at the toilet for pressure water system? Is there 6 feet minimum of head for gravity systems? Fluctuating or high water pressure can cause intermittent problems with the toilet operation.
  • Page 8: Exploded Views

    EXPLODED VIEWS Integral Valve Layout VITREOUS CHINA COLOR CHART Round Elong. Remote Installation China Shell & Shell & Bolt Color Code Only Caps Beige 44333 44334 99064-15 44371 Black 44337 44338 99064-7 44076 Blue 44343 44344 99064-13 44373 Bone 44039 44012 99064-3 93974...
  • Page 10: Hopper Components

    HOPPER REPLACEM ENT CAUTION: Read this Entire Procedure Before Beginning Work! 1. Remove toilet from floor. Place toilet upside down on a sheet of cardboard or other padded surface. 2. Remove nuts from J-bolts on either side of Hopper, lift hopper away from bowl. 3.
  • Page 11 AIR CYLINDER ADJUSTMENT INSTRUCTIONS 1. Remove hopper assembly. 2. Remove clevis pin retaining ring and clevis pin. 3. Inspect the crank arm, clevis and clevis pin for wear. Replace if required. 4. Hold the crank arm in the UP position (flapper closed).
  • Page 12 FLUSH ACTIVATORS 95054 - Commercial Flush Activator 95557 - Palm Button Conversion Kit 95002 - Residential Flush Activator LF-210 Manual P/N 24154 April, 2003...
  • Page 13 POSITIVE FLUSH ACTIVATOR (Commercial) Remote, P/ N 95087 The Detented Positive Flush Activator has been added (as an option) to our product line. It was developed in order to overcome the necessity for the toilet user to hold the standard flush actuator in the deflected position for a definite time (about 2 1/2 seconds) to insure full actuation of the toilet flush cycle.
  • Page 14 AIR WATER SEQUENCE VALVE LUBRICATION 1. Disassemble valve from bottom to top by first unscrewing the Bottom Cap from the Main Body. Then, to unthread the piston from the spool, insert a 3/16" hex into the hex opening at top of spool. Use an adjustable end wrench on the oblong boss on bottom of piston to unscrew piston from spool and push spool up through valve body to remove.
  • Page 15 AIR/ WATER SEQUENCE VALVE OPERATION LF-210 Manual P/N 24154 April, 2003...
  • Page 16 Insert Terms & Conditions. LF-210 Manual P/N 24154 April, 2003...

Table of Contents