Download Print this page

Advertisement

Quick Links

Advertisement

loading
Need help?

Need help?

Do you have a question about the 7'5'' VANTAGE and is the answer not in the manual?

Questions and answers

Summary of Contents for Elite Greenhouses 7'5'' VANTAGE

  • Page 4: Parts List

    PARTS LIST 8x7 10x7 12x7 14x7 16x7 18x7 20x7 Ridge Gutter/Eave Side built in base cill Side angle/Diagonal tie bar Door end built in base Door end cill Rear end built in base cill Rear end horizontal angle Long door end glazing bar Taped together Short door end glazing bar...
  • Page 5 HELPFUL HINTS AND ADVICE Please do take your time and be sure to read all instructions carefully before assembling.  Do not assemble frame in high winds.  The greenhouse frame must be anchored to a permanent foundation. This will not only help ...
  • Page 6 DETAILED ASSEMBLY INSTRUCTIONS The contents of this carton are divided into the different frame assemblies that collectively make up the completed unit. It is recommended that each frame assembly is fully completed before moving on to the next. The frames to be constructed are as follows: SIDE FRAME –...
  • Page 7 SIDE FRAME ASSEMBLY From the main box you require: Pack of side glazing bars marked “side”. Pack of gutters and side angles. Built in base side cills. From the pack of fittings you need: Nuts and bolts and glazing beading. PROCEDURE.
  • Page 8 8. Put nuts on bottom bolts and lightly tighten. 9. Do the same with the other side frame assembly. 10. Make sure that the glazing bars reach both the built in base cill and the eaves in each case. Tighten all nuts. 11.
  • Page 9 SIDE FRAME ASSEMBLY WELL DONE! YOU HAVE SUCCESSFULLY COMPLETED THE 2 SIDE FRAMES!
  • Page 10: Rear End Assembly

    REAR END ASSEMBLY For the construction of this frame you require from the main box: 1 pack of corner bars marked “corner bars”, 1 rear end pack marked “rear end”, 1 rear end built in base cill marked “rear end” and 1 rear end horizontal brace marked “rear end”.
  • Page 11 REAR END ASSEMBLY...
  • Page 12 3. Lay out the components of the frame on the ground as though you were standing on the inside i.e. with the bolt slots uppermost. Ensure that, having correctly identified the roof from the side corner bars, left and right hands (see previous text) you have the roof bars with the letter ‘R’ (indicating ridge) at the top on the outside, i.e.
  • Page 13 12. You can now attach the 3 vertical glazing bars to the built in base cill in a similar manner to 11 above, the longer bar to the middle hole, and the shorter ones to the outer holes. Before attaching the nuts to the shorter glazing bars place the diagonal angles onto the bottom bolt and put a nut on finger tip tight only.
  • Page 14 DOUBLE DOOR END ASSEMBLY Components required Door end cill Built in base cill 3 End glazing bars 2 Rectangular plates with 3 holes 2 Short horizontal braces 2 Roof corner bars (marked ‘R’) 2 Side corner bars (unmarked) 1 Main door track support 1 Top door track 2 Diagonal angles 2 Base legs/corner brackets (approx.
  • Page 15 6. Slide 2 bolts into the top of the 2 long glazing bars. Attach the short horizontal brace to the 1st pre inserted bolt of the long glazing bars and then in turn attach the other end of the horizontal brace to the top bolt of the gusset plate.
  • Page 16 DOUBLE DOOR ASSEMBLY...
  • Page 17 ROOF VENT ASSEMBLY The roof vent pack has 5 pieces of aluminium: and from the main box of fittings you require 6’ of glazing beading, 4 nuts and bolts, 2 casement stay pins, 1 casement stay and 6 M4 stainless steel nuts and bolts.
  • Page 18 DOOR FRAME ASSEMBLY Each Door consists of: 1 unhanded door post 1 handed door post (handed post for left door is different profile to the handed right hand door post) 3 infill panels (1 with pre fabricated lock hole) for lock barrel 1 top and bottom door panels 3 panels of glass which must be fitted during door assembly.
  • Page 19 Before fitting the unhanded door post, offer the glass panels to the door (see glazing plan in booklet for glass size guide on door), slide them in from the side. Carefully attach the unhand- ed door post in the same way as before, ensuring the glass is sitting in the correct position (sitting on the beading channels of the door posts) before tightening the screws.
  • Page 20 DOOR FRAME ASSEMBLY...
  • Page 21 ASSEMBLY OF THE GREENHOUSE UNIT PROCEDURE: 1. With the help of a willing assistant, stand up the rear gable and one of the sides. Standing on the inside of the structure with the gutter facing away from you, insert the eave/gutter bar into the gap between the corner bars, so that the inside flanges which form the angle of the roof and side line up with the bolt slots in the corner bars.
  • Page 22 2. Now stand up the door end assembly and repeat the above procedure. 3. Stand up the other side frame and re- peat the operation outlined above at both corners. 4. The bottom built in base cill of the sides attaches to the corner bars in a similar way.
  • Page 23 You must remember to insert one extra bolt per cantilever T-bar brace and one per vent per bar. For example the 8’ x 7’ would have 3 extra bolts on the middle bar on one side of the ridge and 2 on the middle bar on the non vent side.
  • Page 24 SECURING GREENHOUSE TO PERMANENT BASE The main structure is now complete and it must now be fitted onto its base for securing down. SQUARING UP You must make sure that the structure is level and square. Put one pane of glass (a 610x610mm piece would be sufficient) in each corner of roof, each pane must be level with the small glass re- taining lip just above the gutter and be running parallel with the roof glazing bars.
  • Page 25 PARTITION If you purchased a partition it is at this point that you construct the frame in situ. In the box you will find packs marked “partition corner bars” “partition door end built in base cill” “partition door end” “partition door track” “partition door panels”...
  • Page 26 8. Now attach the built in base to the 2 side base sections of the greenhouse. Firstly bolt an corner bracket/base leg on each end of the partition built in base. If you are on flags or concrete cut off the surplus metal of the legs.
  • Page 27 PARTITION DOOR TRACK This door track is fitted in exactly the same way as the exterior door track so the instructions above apply.. N.B. The small flat bar illustrated is fitted pointing downwards for the partition. (Key point). The small glazing bar above the middle of the door can now be fitted. Put the glazing beading into the grooves and trim to suit.
  • Page 28 FITTING THE DOOR HANDLES The handles are fitted to the infill panel on each door (choose between 1st or 2nd panel down). Position the handle centrally, and mark the hole position. Drill 7mm diameter holes (2 holes per door), then fit the handles, and secure with a nut and bolt.
  • Page 29: Finishing Off

    FINISHING OFF To prevent the door from sliding past its opening, you must fix 2 angle brackets to the door end as- sembly. Insert a cropped head bolt into the bolt channel at the top of the left hand glazing bar (viewed from the inside) and fix and angle bracket as shown in the picture below.
  • Page 30 HORTICULTURAL GLAZING Always handle glass with extreme care as failure to do so can result in injury. Start with the bottom pane of glass on the side, ref A (610 x 610mm) (24” x 24”). Insert 4 stainless steel clips as illustrated, 2 on either side of the pane. The upper 2 clips approx.
  • Page 31 HORTICULTURAL AND MULTI-SHEET TOUGHENED GLASS N.B. P.V.C MUNTINS APPLY ONLY TO TOUGHENED GLASS AND ARE NOT NEEDED FOR HORTICULTURAL GLASS. B2 V4 TOTAL 4 x 7 SIZE 6 x 7 610 x 610 8 x 7 610 x 457 610 x 267 10 x 7 300 x 457 12 x 7...
  • Page 32 TOUGHENED GLASS If you have ordered P.V.C. Bar Capping, you must read the instruction sheet for Bar Capping installation. (FOUND IN THE BOX CONTAINING BAR CAPPING). The main differences in application between the two types of glazing are: Toughened glass is in large sheets. There are no overlaps: where there are two or more panes in a section they are butt jointed with a P.V.C.
  • Page 33 FULL SHEET TOUGHENED GLASS 92 101 102 103 104 TOTAL SIZE 4 x 7 610 x 1489 6 x 7 610 x 904 8 x 7 610 x 610 10 x 7 450 x 457 12 x 7 610 x 1456 14 x 7 450 x 610 16 x 7...
  • Page 34: Optional Extra

    OPTIONAL EXTRA RAINWATER KITS...
  • Page 35 OPTIONAL EXTRA FINIAL AND CRESTINGS DETAIL Place the finial onto the upper flange, level with the end ridge. The slot in the lower part of the finial sits on top of the upper flange. Do likewise with the ridge cresting. The other end of the ridge has the 2 finial fitted in a similar manner to the 1 if this 2...
  • Page 36 1806...