HPM EFD01 Series Instruction Manual

Ceiling exhaust fan

Advertisement

Quick Links

EFD01RDWE/EFD01RDMS/EFD01RDWEKIT
Please read carefully: Read through these instructions completely before commencing installation. Retain for future use. This product should
be installed by a licensed electrical contractor or similarly qualified person.
Specifications
Cat. No.
Colour
Supply Voltage
Power Rating
Max Airflow Rate (Non-ducted)
Max Airflow Rate (Ducted – Ø150mm x 3m)
IP Rating
Duct Requirement
Ceiling Cut-out Size (Ceiling fan)
External grille cut-out size
Projection into Ceiling
Protrusion from Ceiling
Grille Size (Ceiling fan)
Sound Pressure level at 3m
EFD01RDWEKIT includes : 1) External Grill
2) Ø150mm X 3m Duct
3) Cable ties
4) Duct tape
5) Mounting screws
Also available
External wall kit accessory: R621/6D
EFD01SQWE
EFD01RDWE/EFD01RDWEKIT
White
Ø372mm
36 dBA (Tested in accordance with AS1217.5)
Ceiling Exhaust Fan – Ducted
Cat. No: EFD01RDWE, EFD01RDMS,
Instruction Manual
EFD01RDMS
Matt Silver
230-240 V a.c 50Hz
40W max.
3
330m
/hr
3
250m
/hr
IPX4
Ø150mm
Ø298mm
160mm
(EFD01RDWEKIT only)
190mm
26mm
EFD01SQWE, EFD01RDWEKIT
Class II construction
EFD01SQWE
White
350 x 350 mm

Advertisement

loading

Summary of Contents for HPM EFD01 Series

  • Page 1 Ceiling Exhaust Fan – Ducted Cat. No: EFD01RDWE, EFD01RDMS, EFD01SQWE, EFD01RDWEKIT Instruction Manual Class II construction EFD01SQWE EFD01RDWE/EFD01RDMS/EFD01RDWEKIT Please read carefully: Read through these instructions completely before commencing installation. Retain for future use. This product should be installed by a licensed electrical contractor or similarly qualified person. Specifications Cat.
  • Page 2: Please Read Carefully

    20% reduction in the unit’s performance. Please refer to the graph below, an almost linear relationship between back pressure and fan performance proves just how critical correct installation of the exhaust fan is in relation toperformance. EFD01 series (Ducted- Ø150mm x3m) Air Flow(m...
  • Page 3 10. The unit can be installed as shown below in fig. A, fig. B and fig. C. When fitted, the duct outlet can be at the same height or lower/higher than the exhaust fan. 11. Vertical ducting with roof vents will result in reduced fan performance, increased noise and condensation/dripping. fig.A fig.B fig.C...
  • Page 4 figure 8 figure 9 BEFORE AFTER Installation for External Grille (EFD01RDWEKIT ONLY) A suitable position must be found that will suit: 1. The position of the vent on the outside wall. 18mm Ø150mm 2. The location of studs, pipes, wires inside the cavity. Make a circular hole in the outside wall.
  • Page 5: Warranty

    You 1300 369 777 are also entitled to have the goods repaired ifthe goods fail to be acceptable quality and www.hpm.com.au the failure does not amount to a major failure. See the Warranty card enclosed with this product forfurther details.

This manual is also suitable for:

Efd01rdweEfd01rdmsEfd01sqweEfd01rdwekit