Summary of Contents for Frico IHW10

  • Page 1 ..6 ..8 ..20...
  • Page 2 Positioning Fig. 1: The heaters should heat from at least two Type directions for even heating [mm] 1000 1800 Fig. 2: Minimum mounting distance 46,5 ø8 Fig. 3: Bracket measurements...
  • Page 3 0,9 m Fig. 4 Replacing the halogen lamp Fig. 5...
  • Page 4: Timer Control

    Wiring diagrams IH Timer control 1 2 3 Max load 3500W 230V~ Timer control with contactor 1 2 3 230V~ 400V3~...
  • Page 5: Technical Specifications

    Type E-nr (SE) EL-nr (NO) Heat Voltage (2) Amperage (3) Max. filament Weight (5) output (1) temperature (4) [°C] [kg] IHW10 85 701 18 54 325 81 1000 230V~ 2200 IHW15 85 701 19 54 325 82 1500 230V~ 2200 Technical specifications Infrared heater IHF with directed heat distribution, installation height 2.3 –...
  • Page 6 Montage- och bruksanvisning Allmänna anvisningar Montering Läs noga igenom denna bruksanvisning före IH monteras fast på vägg med konsolen. installation och användning. Spara manualen Värmaren kan även monteras på t.ex. ett för framtida bruk. parasoll eller en stolpe, för detta används Produkten får endast användas till det en lämplig U-bult (ingår inte) ihop med som framgår av denna montage- och...
  • Page 7 Byte av halogenlampa Säkerhet Värmelampan i IH är av högsta kvalitet och • Apparaten har vid drift heta ytor! om den inte utsätts för mekanisk påfrestning • Apparaten får ej övertäckas helt eller i form av vibrationer och stötar kommer den delvis med brandfarligt material, då...
  • Page 8 Assembly and operating instructions General Instructions Mounting Read these instructions carefully before IH is mounted on the wall using the bracket. installation and use. Keep this manual for The heater can also be mounted on e.g. future reference. a parasol or a post, a suitable U-bolt (not The product may only be used as set out in included) is used for this together with the the assembly and operating instructions.
  • Page 9 Replacing the halogen lamp Safety The heat lamp in IH is of the highest quality • During operation the surfaces of the unit and unless it is subjected to mechanical are hot! strains in the form of vibrations and impact •...
  • Page 12 Frico AS Tel: +47 23 37 19 00 Russia P .B 6756 Etterstad Fax: +47 23 37 19 10 Frico repr. offi ce in Russia Tel: +7 495 676 00 99 NO-0609 Oslo mailbox@frico.no Lavrov per. 6 +7 495 676 44 48 Norway www.frico.no...

This manual is also suitable for:

Ihw15Ihf10Ihf15Ih series