SERVICE PARTS INFORMATION 8
Thermistor
Check Point : Check Thermistor resistance value
Remove connector and check Thermistor resistance value.
Temperature
[°C]
Thermistor A
-30
1013.1
-20
531.6
-10
292.9
0
168.6
10
100.9
20
62.5
30
40.0
40
26.3
50
17.8
60
12.3
70
8.7
80
6.3
90
4.6
100
3.4
110
2.6
120
2.0
Applicable
Discharge temp. TH
Comp. temp. TH
Thermistors
Resistance Value [ k ]
Thermistor B
Thermistor C
95.6
224.3
50.3
115.2
27.8
62.3
16.1
35.2
9.6
20.7
6.0
12.6
3.8
8.0
2.5
5.2
1.7
3.5
1.2
2.4
0.8
1.6
0.6
1.2
---
---
---
---
---
---
---
---
Heat exchanger. TH
Outdoor temp. TH
02-44
Thermistor D
1013.1
531.6
292.9
168.6
100.9
62.5
40.0
26.3
17.8
12.3
8.7
6.3
---
---
---
---
2-way valve TH
3-way valve TH

Advertisement