Blood pressure measurement module M3500
Machinery and equipment such as 21 visceral function test instrument
Non-invasive blood pressure module
Blood pressure measurement module M3500
Be sure to refer to the instruction manual
Creation or revision date
** March 1, 2012 (third edition)
* October 17, 2011 (second edition)
Approval and notification, etc.
Brand Name
Blood pressure measurement module M3500
Attached document management code
22200BZX00227000_A_01
Approval Number
22200BZX00227000
Approval date
March 2010
General designation for
36551000
Non-invasive blood pressure module
warning
not listed
Contraindications ban
https://translate.googleusercontent.com/translate_c?depth=1&hl=...03%3Fview%3Dbody&usg=ALkJrhhqzooj9yOkvRDfve8nZaQansOoVg#WARNING
13/07/2016 14:23
Page 1 of 8

Advertisement

loading

Summary of Contents for Omron M3500

  • Page 1 Blood pressure measurement module M3500 13/07/2016 14:23 Machinery and equipment such as 21 visceral function test instrument Non-invasive blood pressure module Blood pressure measurement module M3500 Be sure to refer to the instruction manual Creation or revision date ** March 1, 2012 (third edition) * October 17, 2011 (second edition) Approval and notification, etc.
  • Page 2 Blood pressure measurement module M3500 13/07/2016 14:23 Combination medical equipment (not to be used in place of the below) Flammable anesthetic gas and the high concentration used in the oxygen atmosphere [explosion, or there is a danger of fire. ] - In combination with high-pressure oxygen therapy device [explosion, or there is a danger of fire.
  • Page 3 Blood pressure measurement module M3500 13/07/2016 14:23 Classification of equipment ** Blitz degree of protection against by the mounting portion of the classification: arm band B-shaped mounting portion Four. usage environment Temperature: 0 ~ 50 ℃ Humidity: 30 to 85% (non-condensing) Five.
  • Page 4 Blood pressure measurement module M3500 13/07/2016 14:23 Error average of the auscultation: ± 5mmHg within the standard deviation: 8mmHg within Cuff pressure display of error: within ± 3mmHg Quick exhaust Adult (children and infants): The time required in order to rapidly exhaust to 15mmHg from 260mmHg: 10 seconds or less...
  • Page 5 Blood pressure measurement module M3500 13/07/2016 14:23 Important Precautions In the periphery of, the apparatus and the person to be measured, the power supply, such as mobile phones and small radio (PHS terminal that is allowed to use is excluded) because it is not concerned with the cut again.
  • Page 6 Blood pressure measurement module M3500 13/07/2016 14:23 If you have pressure on the arms, it was raised tucked clothing • If you are using a heart-lung machine (because there is no beat) · In the case of pseudo-hypertension Interaction - The periphery of the person at the time of defibrillator use please away from the device and the cords that are connected to the subject and the subject.
  • Page 7 Blood pressure measurement module M3500 13/07/2016 14:23 However, this is a case that has been used in the recommended environment, such as regular maintenance and inspection, there may be a difference through the use situation arises. Matters relating to the maintenance and inspection...
  • Page 8 * Yubinbango617-0002 Kyoto Muko Terato cho Kyunotsubo 53 address phone number Customer Support Center 0120-103-203 (24 hours a day / toll-free) Foreign manufacturers:. OMRON (Dalian) Co., Ltd. OMRON (DALIAN) CO, LTD (People's Republic of China) Sales Source: Omron Colin Co., Ltd. Yubinbango112-0002 Tokyo, Bunkyo-ku Koishikawa chome 12 address No.