Pellas X S.Control TOUCH Operation And Installation Manual

Pellas X S.Control TOUCH Operation And Installation Manual

Burner controller for boilers fuelled with pellets
Table of Contents

Advertisement

1

Advertisement

Table of Contents
loading

Summary of Contents for Pellas X S.Control TOUCH

  • Page 3: Table Of Contents

    INDEX 12.16 CIRCULAR PUMP CONNECTION ..... 31 SAFETY PRECAUTIONS………………………………. …..4 12.17 STB TEMPERATURE LIMITER CONNECTION ... 31 GENERAL INFORMATION ........ 5 12.18 ROOM PANEL CONNECTION ......31 DATA REFFERING TO DOCUMENTATION ..5 12.19 CONTROLLER PARAMETERS ACCESS BY DOCUMENTATION STORAGE ......5 INTERNET NETWORK ........
  • Page 4: Safety Precautions

     The controller must be installed by the boiler producer, in accordance with SAFETY PRECAUTIONS valid norms and regulations  Modification programmed Safety requirements described parameters should only be carried by following sections of this user’s manual. a person acquainted with this user’s Apart from them please obey requirements manual described...
  • Page 5: General Information

    GENERAL INFORMATION damages caused by failing to observe the following user manual. The controller is a modern electronic device DOCUMENTATION STORAGE designed to handling the work of the pellet We advise you to keep carefully this user boiler using help of optical flame brightness manual of installation and maintenance and sensor.
  • Page 7 USER MANUAL OF THE CONTROLLER S.Control TOUCH...
  • Page 8: User Menu Structure

    USER MENU STRUCTURE Fuel selection  Pellet  Agripellets Main menu Cleaning level * Information  Normal Boiler settings  Increased Settings of HUW *  Intensive Summer/Winter Fuel level Mixer settings 1-5*  Alarm level General settings  Calibration of fuel level Manual control Burner cleaning CHIMNEY SWEEP mode...
  • Page 9  Reduction value  Schedule General settings Clock/Data Screen brightness Sound/ Language Software update WiFi* Not available if proper sensor or additional module not connected or the parameter is hidden.
  • Page 10: Controller Maintenance

    CONTROLLER MAINTENANCE Main display window description Pic. 1 Main display window. Key: - reduction of the preset boiler 1. Operation modes: FIRING temperature from the opening of the room STABILIZATION, WORK, BURNING OFF, thermostat contacts– preset room CLEANING, SUPERVISION, PAUSE, temperature is reached;...
  • Page 11: Boiler Start Up - Switching On And Off Of The Boiler

    can be seen in the room panel Room Control raised in order to load the HUW buffer and to TOUCH. load heating circuits of mixers. BOILER START UP - Switching on FIRING UP and off of the boiler FIRING UP mode is for automatic firing up of furnace in boiler.
  • Page 12: Supervision

    If the boiler’s temperature reaches preset Hysteresis H2 and Hysteresis H1 do not have then controller switches to be set. SUPERVISION mode. The Fuzzy Logic mode unlike the Standard mode is not faulty in respect of failing to Controller is equipped with boiler’s power reach the preset boiler temperature due to modulation mechanism –...
  • Page 13: Burning Off

    BURNING OFF Boiler settings Preset boiler → temperature In burning off mode the leftovers of pellet Boiler settings → Power modulation → are burnt and the boiler is prepared to pause Boiler hysteresis or deactivation. Service settings → Burner settings → All the parameters influencing burning off process are grouped in menu: Fuel detection time...
  • Page 14: Activation Summer Function

    small hysteresis value required manually desired pump will activate faster after HUW temperature in mixer’s heating cycle using temperature decrease. parameter Preset temperature of mixer, e.g. 50ºC. Such should be a value to provide 8.14 ACTIVATION SUMMER FUNCTION required room temperature. To activate SUMMER function which allows After connecting a room thermostat, value of feeding...
  • Page 15: Weather Control

    Controller Room Control TOUCH on value of external temperature. Thanks to automatically moves heating curve that by choosing proper heating curve for depending on preset room temperature. The given building, room temperature remains controller relates adjustments to 20ºC, i.e. approximately the same – no matter what for preset room temperature = 22ºC the outside temperature.
  • Page 16: Night Decrease Settings Description

    Preset temperature, counted according to Settings of time control of circular pump are heating curve can be decreased or increased analogical to settings of night reductions. In by controller when it goes beyond scope of defined time periods circular pump limits of temperatures for given cycle.
  • Page 17: Cooperation With Additional Feeder

    Calibration Fill the silo to the level which corresponds to full level of fuel, then set value of parameter: Boiler settings → Fuel level → Calibration of fuel level → fuel level 100% In main window the indicator will be set on 100%.
  • Page 19 USER MANUAL OF CONTROLLER INSTALLATION AND SERVICE SETTINGS S.Control TOUCH...
  • Page 20: Hydraulic Schemes

    HYDRAULIC SCHEMES Scheme 1 Scheme with 4 way steering valve controlling central heating circuit , where: 1 – boiler, 2 – Pic. 8 burner, 3 – controller, 4 – boiler temperature sensor, CT4, 5 – fumes temperature sensor, 6 – servomotor of 4 way valve, 7 –...
  • Page 21: Scheme 2

    Scheme 2 Scheme with heating buffer , where:1 – boiler, 2 – burner, 3 – controller, 4 – boiler temperature Pic. 9 sensor, 5 – fumes temperature sensor, 6 – boiler pump, 7 – heating buffer, 8 – hot water pump, 9 – hot water silo, 10 –...
  • Page 22: Scheme 3

    Scheme 3 Scheme with heating buffer and 5 mixing heating circuits , where: 1 – boiler, 2 – burner, 3 – Pic. 10 controller, 4 – boiler temperature sensor CT4, 5 – fumes temperature sensor CT2S, 6 – boiler pump, 7 – heating buffer, 8 –...
  • Page 23: Technical Data

    and transport should be within scope -15…65 degrees C. Technical data During transport the controller cannot be Power 230V~; 50Hz; exposed to vibrations bigger than typical for transport of boilers. Current consumed by controller 0,04 A Maximum nominal current 6 (6) A CONTROLLER INSTALLATION Controller’s level of protection IP20...
  • Page 24: Installation

    12.3 INSTALLATION The controller is adapted to be installed on flat assembly surface. In order to screw it to assemble surface please undo the screws (3) and carefully lift the cover (1), then undo the plug (4). Then remove the cover (1) in a safe place. Using screws (5) stuck through holes in the cover (2) screw the controller to assembly surface (6).
  • Page 25: Safety Connections

    Connecting wires should not touch with surfaces with temperatures exceeding nominal temperature of their work. Claps on the right side of the device are marked as L, N, 1-19 are designed to connect devises powered with current 230V~. Claps 20-40, D+, D- and RJ are designed to cooperate with low voltage devices (below 12V) Connecting current 230V to claps 20 –...
  • Page 26: Electric Scheme

    12.6 ELECTRIC SCHEME Room Control TOUCH Pic. 13 Controller wiring diagram, where: T1 – CT4 boiler temperature sensor, OS – optical flame sensor, T2 – feeder temperature sensor NTC, PS - vacuum sensor, H – voltage output to signaling alarms or signaling controller operation mode or control the reserve boiler or control the circulation pump, T3 - CT4 hot water temperature sensor, T4 –...
  • Page 27: Temperature Sensors Connection

    The sensor should be screw to the wall. 12.7 TEMPERATURE SENSORS Access to assembly holes is possible after CONNECTION unscrewing the cover of the sensor. Wires of the sensors can be extended by wires with diameter smaller than 0,5mm . Total length of wires in each sensor should not exceed 15m.
  • Page 28: 12.10 Optical Sensor Connection

    12.12 BOILER ROOM THERMOSTAT CONNECTION CT2S-2 (fumes) Room thermostat for boiler circuit can switch Weather Min. Nom. Max. off the burner operation or switch off the CH temperature Ω Ω Ω boiler pump. In order to thermostat switch °C boiler operation select Thermostat...
  • Page 29 controller equipped with transmitter as standard option. Assembly of transmitter should be done by a person with proper qualifications. According to valid norms and regulations. Control of reserve boiler by setting the Output H1 A on Reserve boiler. Menu → Service settings → Output H1 Additionally to activate control over reserve boiler set the parameter Reserve boiler activation temperature on value different...
  • Page 30: 12.14 Alarms Signal Connection

    Pic. 19 External alarm device connection, where: 1 – controller, 2- external alarm device, 3- relay. Assembly transmitter must be performed by a qualified Electrical scheme controlling Pic. person accordance with switching valve of additional boiler, where: 1- current legislation. controller, 2- additional boiler, 3- relay, 5- servomotor switching...
  • Page 31: 12.16 Circular Pump Connection

    controller cooperates only with servomotors of mixing valves equipped with Calibration of valve indicator position: end switchers. Using other servomotors is Indicator of valve position is in the menu: forbidden. Servomotors with full circle scope Information. For mixer 1 after some time it of 30 to 255s can be used.
  • Page 32: Controller Parameters Access By Internet Network

    Controlling panel for the boiler Alarm signal Fuel level indicator Attention: diameter of wires for connecting Room Control TOUCH should be at least 0,5mm Maximum length of wires to Room Control TOUCH panel should not exceed 30m. This length can be bigger when wires with bigger diameter than 0,5mm2 are used.
  • Page 33: Structure- Service Menu

    Grate *  Operation grate STRUCTURE- SERVICE MENU  Fan in operation grate  Blowing operation – Service settings supervision Burner settings  Blowing pause – Boiler settings supervision CH and HUW settings Lambda probe * Buffer settings *  Operation with Lambda Mixer settings 1-5* probe...
  • Page 34 Temperature of activating the Output H1 CH pump Output H2 and H3 * CH pump pause during loading H1 output configuration HUW * Boiler reserve Minimum temperature of HUW * Alarms Maximum temperature of HUW * Circulation pump Increase of boiler temperature Signaling operation mode from HUW and mixer H2 and H3 output...
  • Page 35: Service Settings

    SERVICE SETTINGS 14.1 BURNER SERVICE SETTINGS Firing up Description  Ignition test time Time for checking if furnace is hot. Only fan is operating Threshold of flame detection in % of light, when the controller deems the  Flame detection furnace as hot.
  • Page 36  Burning off cleaning time Fan operation time during furnace burning off  Cleaning airflow Fan power in % during furnace cleaning in burning off and firing up Supervision After this time, when the controller is in SUPERVISION mode, the ...
  • Page 37: Boiler Service Settings

    Activates the operation mode with the vacuum sensor. Once the mode is Vacuum sensor activated, the rotational speed of the exhaust fan is set by the controller to reach the required value of the vacuum in the combustion chamber. Defines the minimum value of the vacuum in the combustion chamber. ...
  • Page 38: Buffer Service Settings

    pump during feeding HUW silo. CH pump after this time will activate on constant, programmed time of 30s. Available after CH sensor connecting. It is a parameter by which it can Min. HUW temperature be reduced setting too low preset HUW temperature. Available after connecting HUW sensor.
  • Page 39: Mixer Service Settings

    14.5 MIXER SERVICE SETTINGS Mixer support  Off Mixer servomotor and pump are not active Applicable when mixer cycle powers heating installation of CH. Maximum temperature of mixer cycle is not limited, mixer is fully opened during alarms i.e. boiler overheating. Attention: do not activate ...
  • Page 40: Others

    However, avoid too frequent movements of servomotor, which can shorten its long-life usage. Regulation is undertaken only when measured temperature of mixer cycle will be higher or lower than preset value by the value bigger than mixer dead zone. 14.6 OTHERS Options available: ...
  • Page 41: Software Replacement

    SOFTWARE REPLACEMENT Software replacement can be made by a micro memory card only microSD HC. Attention: replacement software can only be done by a qualified person, observing every safety means related to danger of electricity shock! To replace the program, it is needed to disconnect electricity from the controller and disassembly the TOUCH panel from the cover of the controller, put the memory card into...
  • Page 42: Alarms Descriptions

    Alarm is deleted automatically after burner ALARMS DESCRIPTIONS temperature decrease by 10C. 16.1 FUMES MAX. TEMP. EXCEEDING Alarm is deleted automatically after alarm occurs after exceeding burner temperature decrease by maximum fumes temperature. Turns off the 10C. fan. aims protect fumes temperature sensor from damage due to the Function...
  • Page 43: Communication Loss

    OTHER 16.6 COMMUNICATION LOSS Controlling panel is connected to remaining 17.1 POWER STOPPAGE electronics by digital communication joint In case of power stoppage the controller RS485. In case of damage of this wire on the returns to operation mode in which it was screen following information...
  • Page 44: Lambda Sensor Λ

    LAMBDA SENSOR λ Burner efficiency increased connecting additional lambda sensor module. Connect the module according to point 12.6. Lambda sensor is to be activated in: Service settings → Burner settings → Lambda probe If parameter Work with Lambda probe is set on “ON”...
  • Page 45: Possible Faults Description

    POSSIBLE FAULTS DESCRIPTION Symptoms Tips Check: There signs  If line fuses are not blown, replace if necessary operation of device despite  If the wire connecting panel with the executive module is plugged connection to the network. correctly and if module is not damaged. On the screen of the Room Check: Control TOUCH controlling...
  • Page 46: Controller Configuration By Boiler

    HUW pump is not working,  Set the parameter Prolongation of HUW work = 0 even if HUW silo is loaded CONTROLLER CONFIGURATION BY BOILER PRODUCER The producer of boiler / burner should adjust program parameters in controller to given type and power of the burner.