Step 3. Connect Valve Wires To Timer; Valve Connections; Timer Connections - Rain Bird SST-600in Setup & Operation Instructions

Simple to set timer (sst)
Hide thumbs Also See for SST-600in:
Table of Contents

Advertisement

C
Unscrew the wire-nuts from the three wires connecting the
power cord to the timer.
D
Remove the metal bracket holding the power cord to the
back of the wiring compartment and pull the cord out
through the bottom of the cabinet.
E
Route the three wires from an external power source into the
wiring compartment.
F
Using the wire-nuts, connect the external power wires to the
internal connection wires inside the wiring compartment.
c

WARNING: Be sure to connect the color coded external
wires to the same color internal connection wires, as follows:
Black wire (power)
White wire (neutral)
Green wire (ground)
G
Verify that all wiring connections are secure, then replace the
wiring compartment cover.
INTERNAL
TRANSFORMER
INTERNAL
CONNECTION
WIRES
WIRING
COMPARTMENT
EXTERNAL
POWER WIRES

Step 3. Connect Valve Wires To Timer

Valve Connections

A
Use direct burial cable to run wiring from the timer to valves
in the field.
B
Connect a color coded wire from the direct burial cable to
either wire on the valve.
C
Connect the remaining wire on each valve to a "common"
wire which then connects to the timer.


NOTE: Use water-tight connectors for all wire splice connec-
tions. Depending on your landscape setup, you may need to
run extension wires for the power and common connections.

Timer Connections

A
Use a wire stripper to strip away approximately 1/4" of insu-
lation from the end of the valve wire.
B
Push the exposed end of the color coded wire from each
external valve (or zone) into the corresponding zone number
on the terminal block.
2
2
SST User Manual
SST user manual (EN) web.indd 2
WIRE NUTS
TO POWER
SOURCE


NOTE: To insert or remove a wire, use a screwdriver to press
down on the connection release.
1/4"
c

WARNING: To prevent damage to the timer, connect only
ONE valve to each open zone slot on the terminal block.
C
Connect the common wire to one of the COMMON slots on
the terminal block.
D
Check that all wiring connections are secure.


NOTE: Do not remove the yellow jumper wire on the ter-
minals marked RAIN SENSOR unless you're connecting an
optional rain sensor. See "Rain Sensor" on page 3 for
more information.
VALVE AND TIMER CONNECTIONS
POWER
ZONE 1
POWER
VALVE
ZONE 2
VALVE
TERMINAL
BLOCK
DIRECT
BURIAL
CABLE
WIRES TO
ZONES 3 & 4
COMMON WIRE
WATER-TIGHT
CONNECTORS
10/11/2016 8:17:24 PM

Hide quick links: