Stalgast 9745110 Maintenance Manual page 30

Gas pasta boiler
Table of Contents

Advertisement

Available languages

Available languages

3.
Adjust the minimum flow in the control valve - by tightening or loosening the screw located next to
the knob on the gas valve.
Remove the knob from the gas valve to get to the bypass (sometimes it is necessary to dismantle the
panel)
Screw in the appropriate by-pass in accordance with Table 4.1
By - pass
4.
Adjust the gas flow on the pilot burner - replace the pilot nozzle according to table 4.1; after unscre-
wing screw 4 in accordance with table 4.1
Adjustable sleeve position
Pilot
- 30 -
Gas valve