6.5 inch (16.5 cm)
Min. Diameter Hole in Wall
SIDE WATER OUTLET
C
DRAIN VALVE
E & F
SIDE WATER INLET
1/2" GAS
CONNECTION
G
D
Horizontal Installation Only
Optional Kits:
Part Number
Description
243-42516-00
Kit F – Telescopes from 4
243-42517-00
Kit G – Telescopes from 6
243-42514-00
Kit H – Telescopes from 13
243-42512-00
Kit I – Telescopes from 49
Energy Saver Direct Vent Models
NATURAL GAS
Imp.
U.S.
Gal.
Gal.
Model
Cap.
Cap.
Liters
Number
DH1-504T6BN
(LP)
40
48
182
DH1-65T6BN
54
65
246
(LP)
DH1-75S6BN
62
75
284
For 10 year models, change suffix from "6" to "10".
All propane gas heaters are equipped with Cast Iron Burner.
Change suffix "BN" to "CX".
Suitable for Water (Potable) Heating and Space Heating
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced
into this system. This unit may NEVER be connected to any existing heating system or
component(s) previously used with a non-potable water heating appliance.
General
All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are
NPT on 11" (703mm) centers on top of unit, all gas connections
CGA). Recovery based on rated efficiency.
Meets NAECA requirements. All natural gas models meet SCAQMD requirements.
Dimensions and specifications subject to change without notice
in accordance with our policy of continuous product improvement.
6-Year Limited Warranty on
Component Parts
BRADFORD WHITE CORPORATION has
a 6-year warranty on replaceable parts–
thermostat, burner, dip tube, drain valve
and piezo igniter. These quality
components are manufactured for us by
industry leaders and will be replaced in
the event of failure during the parts
warranty period (exclusive of shipping
and re-installation cost).§
§ Some states do not allow limitations on warranties. See complete copy of the
warranty included with this product. Indicated warranties apply to USA, Canada and
Puerto Rico installations.
Vitraglas
®
and Hydrojet
®
are registered trademarks of Bradford White
©2006, Bradford White Corporation. All rights reserved.
105-B-HIDV-1106-A
X
11 1/2
11 9/16
7 3/16"
Y
Boot Extension
H
A
B
3
" to 5
11
"
4
1 6
1
" to 9
3
"
2
1 6
3
" to 23
11
"
4
1 6
13
" to 95
13
"
1 6
1 6
GPH Rec.
50˚C/90˚F Rise
Ht. to
Center Line
Input
Imp.
US
of Vent
BTU
KW
Gal.
GPH LPH
in.
50,000
43
53
201
75
1
14.7
4
55,000
47
58
220
78
16.1
1
4
60,000
51
63
238
75
1
17.6
2
1
6 or 10-Year Limited
Tank Warranties
BRADFORD WHITE CORPORATION
LIMITED WARRANTY: Protects your
investment in a quality glass-lined
heater. If the tank leaks for reasons of
faulty materials, workmanship, or
corrosion within the warranty period, the
heater will be replaced with a compara-
ble heater of our manufacture (exclusive
of shipping and re-installation cost).§
®
Corporation.
The standard vent kit (239-42979-00) is ordered and shipped separately. The
components are as follows: 4" vent tube*, 6" Air Intake Tube, Vent Terminal, Inner Wall
Term Mounting Flange, Outer Wall Term. Mounting Flange, Vent Terminal Hardware,
RTV Silicone Sealant, 4" Vent Elbow and a 6" Air Intake Elbow. The vent tube and air
intake tube telescopes from 13 3/4" to 23 11/16".
16 1/4
17 3/16
order
11 9/16
kit F
16 5/16
*order
17 1/4
kit F (2)
18 1/16
order
20 3/4
kit F & G
25 5/16
order
35 1/4
kit F
38 1/16
order
57 15/16
kit H & F
61 3/8
order
107 3/8
kit I & F
* (2) = Order two of the kits referenced.
* (3) = Order three of the kits referenced.
The bold text above show what kit(s) are needed in addition to the standard vent and air
intake tubes. If the standard vent and air intake tubes are not used in the venting system
(those that do not have bold text) they can be discarded or saved.
For vent distances not found in the selection chart above, please contact the Product
Management Department for sizing recommendations.
CEC listed.
A
B
C
D
Ht. to
Ht.to
Jacket
Top of
Gas
Dia.
Heater
Conn.
mm.
in. mm.
in. mm.
in. mm.
58
3
1492
1911
20
508
15
1
387
4
4
1988
22
559
62
1557
15
387
1
4
59
1499
1918
24
1
622
15
1
387
2
4
(LP)
DH1-504T6CX 48,000 BTU/H 14.1 KW 41
DH1-75S6CX
" (13mm). All models design certified by CSA International (formerly AGA and
2
Horizontal "X"
18
25 1/4
37 3/4
20 11/16
35 3/16
57 7/8
order
no add'l
order
kit G
kit req'd
kit H
order
order
order
kit G & F
kit F
kit H & F
order
order
order
kit G (2)
kit G
kit G & H
order
order
order
kit G
kit H
kit H (2)
order
order
order
kit H & G
kit H (2)
kit H (3)
order
order
order
kit I & G
kit I
kit I & H
78% Recovery Efficiency for all models.
E
F
G
Ht. to
Space
Space
T&P
Htg.
Htg.
Conn.
Outlet
Inlet
in. mm.
in. mm.
in. mm.
52
1
1327
52
1
1327
15
3
400
4/6
4
4
4
56
1422
56
1422
15
400
4/6
3
4
52
1321
52
1321
16
1
419
4/6
2
Propane Gas Inputs
50°C Rise and 90°F Rise
Imp.
GPH
57,000 BTU/H 16.7 KW 48
Ambler, PA
For U.S. and Canada field service,
contact your professional installer or
local Bradford White sales representative.
Sales/800-523-2931
Fax/215-641-1670
Technical Support/ 800-334-3393
Fax/269-795-1089
Warranty/800-531-2111
Fax/269-795-1089
International:
Telephone/215-641-9400
Telefax/215-641-9750
Fax on Demand:
888-538-7833
www.
bradfordwhite.com
Mississauga, ON
Sales/Technical Support
866-690-0961
905-238-0100
Fax/905-238-0105
www. bradfordwhitecanada.com
61 5/16
107 5/16
order
kit I
order
kit F & I
order
kit G & I
order
kit I
order
kit H & I
order
kit I (2)
Vent
Approx.
Dia.
Shpg.
Wt.
in. mm.
Lbs. Kg.
102/152
197/89.4
102/152
243/110
102/152
281/127
Recovery at
U.S.
Liters/
GPH
Hr.
50
189
60
227
3
" (19mm)
4
Printed in U.S.A.

Advertisement

loading

This manual is also suitable for:

Dh1-504t6bnlpDh1-504t6bnDh1-65t6bnDh1-75s6bnDh1-75s6bnlp