Usage

2
Usage
2.1

General information

Before installing the appliance and flue gas routing, consult the
responsible building authorities and district flue gas inspector to
establish whether there are any objections.
The flue duct kit is a component of the CE-approved system. Therefore,
only genuine flue duct kits may be used.
The permissible maximum balanced flue line depends on the appliance
and the number of deflections in the balanced flue. For calculation, see
chapter 5 from page 11.
2.2

Wall mounted gas fired condensing boiler

Wall mounted gas fired condensing boiler
ZSB 30-2 A
ZWB 37-2 A
Table 2
2.3

Combination with flue duct kits

The following flue accessories can be used in flue gas systems for these
condensing boilers:
• Flue accessories, coaxial pipe Ø 60/100 mm
• Flue accessories, coaxial pipe Ø 80/125 mm
• Flue accessories, single pipe Ø 80 mm
For flue gas/flue gas accessory designations and the part numbers of the
original flue gas accessories, see the current pricelist.
4
3

Installation

3.1
General information
▶ Follow the instructions for the flue duct kit.
▶ Route horizontal flues with 3 ° gradient (= 5.2 %, 5.2 cm per metre)
in the flow direction of the flue gas.
▶ Insulate the combustion air line in humid rooms.
▶ Install cleaning apertures where they will be easily accessible.
▶ When installing cylinders, take their dimensions into consideration
when installing flue accessories.
▶ Before fitting the flue kits:
Apply a thin coating of solvent-free grease (e.g. Vaseline) to the joint
seals.
▶ When fitting the balanced flue, always push the pipe fully home into
the sockets.
Condens 5000 W – 6720644146 (2019/03)