Download Print this page

LG 27MK60TM Service Manual page 16

Chassis: lm8ea
Hide thumbs Also See for 27MK60TM:

Advertisement

2
6.6 E
PROM Data Read
6.6.1 Signal TABLE
START 6E
Delay 150ms
START 6F
6.6.2 COMMAND SET
Adjustment contents
No.
1
EEPROM READ
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
6.6.3 Use
2
Read E
PROM's specific area as unit of 128(80h)-byte. ( 84h )
6.6.4 EDID Write
EEPROM access by using DDC2B protocol
1-Byte write
START A0
L : 0x00~0x7F
D : data
8-byte write
START A0
L : 0x00,0x10,....0x70
6.6.5 EDID Read
DDC2B Command.(A0/A1)
START A0
- 128 Byte transfer of EDID Buffer of MICOM
A
50
A
84
A
----------------------------------------------------------------------
A
D1
A
CMD(hex
E7
A
L
D
A
A
A
L
A Data A
A
00
START A1
03
A CMD A ADH A ADL
128 Bytes
ADH(hex)
ADL(hex)
)
A0
80
A2
80
A4
80
A6
80
A8
80
AA
80
AC
80
AE
80
STOP
A
Data8
A
....
A
Data1
. . .
- 16 -
A
CS
Dn
Explanation
0
0-Page
0~7F Read
0-Page 80~FF Read
0
1-Page
0~7F Read
1-Page 80~FF Read
0
2-Page
0~7F Read
2-Page 80~FF Read
0
3-Page
0~7F Read
3-Page 80~FF Read
0
4-Page
0~7F Read
4-Page 80~FF Read
0
5-Page
0~7F Read
5-Page 80~FF Read
0
6-Page
0~7F Read
6-Page 80~FF Read
0
7-Page
0~7F Read
7-Page 80~FF Read
STOP
Data128 A
CS
Copyright © 2018 LG Electronics Inc. All rights reserved.
Only training and service purposes
STOP
A
STOP
A
A
STOP

Hide quick links:

Advertisement

loading

This manual is also suitable for:

27mk60tmb