Skin & vein replacement kit

Advertisement

REMOVING THE SKIN AND VEINS
1. Remove the two thumb screws that
hold the hand on the stand.
(See Figure 7.)
2. Remove the old skin by cutting it with
a pair of sharp scissors. Start at the
wrist and cut up to the end of the
middle finger. Carefully peel the old
skin off the core and discard it.
3. Remove the old "veins" from the
grooves and discard them.
REPLACING THE VEIN TUBING SYSTEM
1. Start installing the new tubing on the left side
of the hand. Leave about 12" of excess tubing
out of the vein channel. (See Figure 1.)
2. The vein will follow the channel around the
ring finger back down along the middle of
the hand. (See Figure 2.) The vein continues
around the lower loop at the wrist, back up
around the thumb, and around the upper loop
at the wrist. (See Figure 3.) Now the vein will
overlap itself at the middle of the hand and continue around the middle finger. (See Figure 4.)
3. The vein will now go around the loop at the back of the hand and continue around the index finger.
(See Figure 5.) Now run the vein down the channel to the wrist (the vein will overlap the two loops at
the wrist) and out the end of the vein channel on the bottom of the wrist.
Figure 1
Figure 3
Figure 2
Figure 4
Figure 5