Page 2
Please read carefully before using the machine. Familiarise yourself with this unit`s operation, its particular features and limitations. Should you require any further information please call our Rozone Support Team on 0121 526 8181 For Technical Support or to order more consumables...
Change the ROWASHER Microbe Filter Mat EVERY MONTH ................To Maintain Cleaning Performance ORIGINAL OPERATING INSTRUCTIONS CONTENTS 1. Safety Instructions 2. Power Connection 3. Proper Use 4. Function 5. Machine Diagram and Parts 6. Setting Up 7. Operation 8. Energy Saving Mode 9.
Please read the operating instructions for your ROwasher before using it. In these operating instructions, the designation “the ROwasher” always refers to the ROw500. The unit should only be operated by those authorised to do so. Warning information on the machine provides important directions for safe operation.
Do not fill the tank with solvents, flammable or explosive liquids. The ROwasher is not meant for the disposal of used oil. If large quantities of oil, petrol, engine oil, anti-freeze agents or similar substances are added to the system...
ROwash Microbe Filter Mat which traps large particles of grease and oil along with any particulate matter larger than 50 microns. Grease and oil is washed off parts into the ROwasher tank and then degraded by the microbes into carbon dioxide and water.
Change the ROWASHER Microbe Filter Mat EVERY MONTH ................To Maintain Cleaning Performance 5. MACHINE DIAGRAM AND PARTS 1. Sink Top Part No. 11090802 XL : 11090804 2. Nozzle Part No. 11090857 3. Brush Part No. 11090855 XL : 11090856 4.
WARNING – Adding any other cleaning solution or liquids such as solvents, disinfectants and alkaline cleaners can deactivate the microbes and the bio- remediation of grease and oil will be affected resulting in the ROwasher not working properly. Plug into the correct mains supply. To avoid damage, the machine must be plugged into the power source stated on the machine control box label.
DO NOT USE THE ROWASHER AS A WASTE DUMP Do not turn the ROwasher off unless it is for safety reasons, moving or servicing. The optimum temperature for the activity of the microbes and therefore breakdown of oil and grease is between 37°c and 42°c, therefore the ROwasher must always be left switched on.
Page 10
Change the ROWASHER Microbe Filter Mat EVERY MONTH ................To Maintain Cleaning Performance 9. OPERATIONAL GUIDE FOR CONTROL BOX Output Description Notes LED 1 LED 2 Sound FLUID TEMP Initialisation sequence will start immediately after machine is powered on. At the end of...
Please dispose of used Filter Mat according to local authority regulations for waste containing mineral oil (see “Instructions for Disposal”) Place new ROwasher Microbe Filter Mat white side up onto the filter support grid Replace the sink tray YEARLY - Annual maintenance check on the Rowasher recommended...
Replace the Filter Mat (see section “Maintenance and Care/Monthly”) 13. MOVING OR TRANSPORTING Unplug the ROwasher from the electrical socket ; roll up the power cord. Take off brakes. Carefully wheel to desired location taking into account the influences of the surrounding area and ground conditions to ensure the ROwasher does not tip over.
Change the ROWASHER Microbe Filter Mat EVERY MONTH ................To Maintain Cleaning Performance 15. TROUBLESHOOTING GUIDE Output Description Notes LED1 LED2 Sound Problem Indicators Solution Flashing Liquid level is too low. a) Check fluid level. Solid Green every Beep Application stopped, heater b) Check level sensor position.
................To Maintain Cleaning Performance 16. ACCESSORIES AND SPARE PARTS Only use accessories and spare parts which have been approved by Rozone Ltd. This ensures that the ROwasher operates correctly and safely. 17. WARRANTY We will repair all machine appliance failures within the warranty period free of charge, provided that the failure is caused by faulty parts or defects in fabrication.
Page 15
IP65 P.A.T. TESTING The ROwasher machine is of a CLASS 1 construction and due to the weight of the machine when full should be classed as stationary. We recommend a minimum time of 12 months for combined testing and inspection and monthly for the formal visual...
Change the ROWASHER Microbe Filter Mat EVERY MONTH ................To Maintain Cleaning Performance 21. ELECTRICAL BOX DIAGRAM For Technical Support or to order more consumables Tel: +44 (0)121 526 8181 www.rozone.co.uk...
Need help?
Do you have a question about the ROWASHER and is the answer not in the manual?
Questions and answers