Introduction
About this document
 In addition to this document, the Manuals for HISAKA PHEs consist of the following six documents. Read them thoroughly and
understand the precautions regarding the safety of the equipment and its functions before handling the equipment.
1 Installation Manual, 2 Operation and Maintenance Manual, 3 Gasketting Manual, 4 Plate Cleaning Manual,
6 Mixed Gasket Materials Manual, 7 Strainer Maintenance Manual.
You
can also download these documents on our company website.
 This document is the operation and maintenance manual for "Slit-in" type plates of plate heat exchangers (PHE) to which gaskets
are installed without adhesives. Refer to the separate operation and maintenance manual for food product PHE
(FX-A Series).
 This document is created for a person who fully understands the language it is written in. If a person, who is not able to understand
the language written herein, will handle the equipment, please provide safety instructions to the personnel/operators.
 The PHE supplied may differ from the drawings and pictures in this document depending on the optional parts if any. Also, for the
purpose of explanation, the drawings and pictures in this document may omit the details, accessories, or the like.
 Changing the contents of this document, in part or in whole, or using this document for anything other than its intended purpose is prohibited.
About gasket use
 To prevent injury and damages, do not use the gaskets other than for their intended purpose and specifications. Also, during
maintenance, follow the instructions of related documents.
About worker limitations
 PHE maintenance should be carried out by a worker who has received training in safety and danger prevention.
 Work in high places should be carried out by a worker who fully understands the danger of the work and has received training in
safety and danger prevention.
Export Regulations on the Equipment
 In case of export of HISAKA PHE and its component parts such as plate, gasket and so on, please follow the local law and
regulations.
Disposal of the Equipment
 Do not incinerate gaskets. Incinerating gaskets releases toxic gas and is extremely dangerous.
 Any unnecessary gasket should be disposed as industrial waste in accordance with international, national, prefectural, and
municipal regulations.
Disclaimer
 HISAKA accepts no liability for any failures in the function or performance of the equipment caused by use of any other than
genuine parts.
 HISAKA accepts no liability for any injuries or damage borne by the user, caused by use of any other than genuine parts.
 HISAKA accepts no liability for any failures in the function or performance of the equipment caused by use of this equipment in a
manner that does not adhere to the procedures indicated in this manual.
5 "Slit-In" Type Gasketting Manual
http://www.hisaka.co.jp/english/
Plate Heat Exchanger

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UX-005A and is the answer not in the manual?

Questions and answers

Summary of Contents for HISAKA UX-005A

  • Page 1  Work in high places should be carried out by a worker who fully understands the danger of the work and has received training in safety and danger prevention. Export Regulations on the Equipment  In case of export of HISAKA PHE and its component parts such as plate, gasket and so on, please follow the local law and regulations. Disposal of the Equipment ...
  • Page 2: Table Of Contents

    “Slit-in” Manual Table of Contents Safety Precautions “Slit-in” Plates and Gaskets “Slit-in” Gasketting Procedures P2 to 4 “Slit-in” Gasket Removal Procedures Plate Disassembly and Assembly D-Plate Gasket Installation Procedures Other Precautions Inquiries P5 to 7...
  • Page 3: Safety Precautions

    Safety Precautions Read through this manual carefully before use and use the PHE properly as indicated. If you have any questions, please inquire with our company. Precautions are categorized using the following symbols. WARNING This symbol indicates content where mishandling could result in death or severe injury. CAUTION This symbol indicates content where mishandling could result in injury or property damage.
  • Page 4: "Slit-In" Plates And Gaskets

     “Slit-in” plates have slits (holes) that are used for fixing gaskets to the plate.  These slits (holes) are located on the outside of the plate gasket groove and in the port holes (excluding UX-005A and UX-01A). Gaskets ...
  • Page 5 Fig. 5 Procedures for Setting Hook-Lock Type Protrusions Procedures for Setting Gaskets without Port Hole (Excluding UX-005A and UX-01A) 1) In case of no slit on plate, cut the protrusion of Gasket (* part in Fig.6) with scissors as below Fig.6 and 7.
  • Page 6: "Slit-In" Gasket Removal Procedures

    “Slit-in” type, adhesive is necessary for D-gasket setting. Refer to "3. Gasketting Manual" for gasketting by adhesive. Table 2 D-Plate Gasketting Procedures for “Slit-in” type Models: UX-005A, UX-30A, SX-40A and SX-70A [NOTE] The figure shows model UX-005A. Plate type and  protrusion position are different depending PHE model. Adhesive Slit Refer to "3.
  • Page 7: Inquiries

    Inquiries Contact info for inquiries HISAKA WORKS, LTD., Heat Exchanger Div., Sales Department Osaka: 2-1-48, Higashi-Konoike-cho, Higashi-Osaka, Osaka, 578-0973, Japan Tel : +81-(0)72-966-9601 Fax : +81-(0)72-966-8923 Tokyo: KYOBASHI OM BLDG. 1-19-8, Kyobashi, Chuo-Ku, Tokyo, 104-0031, Japan Tel : +81-(0)3-5250-0760 Fax : +81-(0)3-3562-2759 Nagoya: Fujifilm Nagoya Bldg.
  • Page 8 No.117 Xiangyuan Road, Changshu National New & Hi-tech Industrial Development Zone, Changshu City, Jiangsu Province 215542, P.R. China Fax : +86-512-5213-3008 HISAKA WORKS(CHINA)CO., LTD. SHANGHAI BRANCH (CHINA) Tel : +86-21-5211-0701 Room 1603, Shanghai Oriental Center, 699 West Nanjing Road, Shanghai 200041, P.R. China...
  • Page 9 Please inform us the "MFG. Number" and "Model" described on the nameplate or Plate Arrangement Drawing and Assembly Drawing.  For more information Hisaka Works, Ltd. official homepage (http://www.hisaka.co.jp/english/).  Customer's memo Please fill in the table below with PHE information.
  • Page 10 Hisaka Works, Ltd., Heat Exchanger Division acquires both ISO9001 and ISO14001 certification. HE-ME003700R4...