Download Print this page

HARDER & STEENBECK 20A Operating Instructions Manual page 18

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
Malfunctions
Compressor becomes too hot
Note: No claim is made to the completeness of the possible malfunctions listed here.
Technical data
The following is a table of performance values of individual compressor types (according to manufac-
turer specifications).
Model
Voltage
Volt
20A
230/50
25A
230/50
HTC 30A
230/50
30A
230/50
HTC 50A
230/50
50A
230/50
100A
230/50
Subject to change and correction.
GB
18
Possible causes
Oil level incorrect
Wrong oil type
Air filter dirty
Room temperature too high
or air supply is
inadequate
Compressor excessively
overloaded
Power
Suction
capacity
Watt
litre
135
17
135
17
200
25
200
25
340
50
340
50
680
100
Remedy
Check oil level, top up oil if
necessary
Drain oil and replace with com-
pressor oil
Change air filter
Ensure that air supply is
adequate
Check whether compressor is
suitable for load
Pressure
Tank
capacity
bar
litre
6
1,5
6
3,5
8
9
8
4
8
15
8
24
8
24
Noise
Weight
level
net
dB (A) 1m
kg
38
18
38
16
40
19
40
19
43
26
43
29
43
48

Advertisement

loading

This manual is also suitable for:

25a30a50a100aHtc 30aHtc 50a