Screw Terminal - Baumer isiLine 34 Operating Instructions Manual

Hour counter
Table of Contents

Advertisement

Available languages

Available languages

ISI34, ISI35
Input specification, terminal assignment and adjustable time ranges (AC versions)
The time range is set via a control input (screw terminal 5).
No. 1

Screw terminal

designation
INP A
AC/DC
Model
ISI34.013AX01
ISI35.013AX01
Table 3
Screw terminal 1:
Timer Enable Input: time measurement as long as the level at
this input is high.
Optocoupler input
10 ... 260 V AC/DC
galvanic isolation, active for
high signal
Low level:
0 ... 2 V AC/V DC
High level:
10 ... 260 V AC/DC
Input resistance:
approximately 160 kOhm
Screw terminal 2:
Common AC/DC, common connection for the optocoupler inputs
(screw terminals 1 and 3)
Screw terminal 3:
Reset input:
active for high level.
Optocoupler input: 10 ... 260 V AC/DC galvanic isolation,
active for high signal
Min. pulse duration: 16 ms
Max. frequency:
approximately 30 Hz
Low level:
0 ... 2 V AC/V DC
High level:
10 ... 260 V AC/DC
Input resistance:
approximately 160 kOhm
Screw terminal 4:
Electrical locking of the reset key Contact input / Open Col-
lector NPN (switching at 0 V DC)
Low level:
0 ... 0,7 V DC
High level:
3 ... 5 V DC
Input resistance:
approximately 2,2 MOhm
Input not active:
Reset key locked
Input in contact with GND:
Reset key unlocked
10
No. 2
No. 3
No. 4
Common
INP B
Reset
AC/DC
AC/DC
Enable
www.b umer.com
No. 5
Time range (Mode)
contact with
99999,99 h
not active
contact with
=
9999999,9 s
9999 h59m59s
Screw terminal 5:
Time range switching (Mode)
Contact input / Open Collector NPN
(switching at 0 V DC)
Low level:
0 ... 0,7 V DC
High level:
3 ... 5 V DC
Input resistance:
approximately 2,2 MOhm
Function:
see table 3
Remark:
If the time range is changed during operation, the device must be
reset, otherwise the counting value will not be reproducible.
Screw terminal 6:
Common GND connection for screw terminal 4 (reset key
locking input) and screw terminal 5 (time range switching).
Screw terminal 7:
(–) external power supply for the backlight option
Screw terminal 8:
(+) external power supply for the backlight option
(24 V DC ±20 %, 50 mA)
No. 6
No. 7 No. 8
GND
BL
GND
=
GND
=
BL
+

Advertisement

Table of Contents
loading

This manual is also suitable for:

Isiline 35Isi34Isi35