Offgridtec PWM Pro Series Manual page 13

Charge controller
Table of Contents

Advertisement

Available languages

Available languages

Battery Voltage Parameters
These values apply to a 12V system at 25°C. For a 24V system the values
have to be doubled.
Battery Type
Overvoltage disconnect
Max. charging voltage
Restart after overvoltage
Equalizing load voltage
Boost load voltage
Float load voltage
Boost-restart load voltage
Under voltage restart
Under voltage warning
Restart
Voltage
Under voltage warning
Undervoltage disconnect
Discharge threshold votlage
Equalizing period
Boost period
Sealed
Gel
Flooded
16.0V
16.0V
16.0V
15.0V
15.0V
15.0V
15.0V
15.0V
15.0V
14.6V
——
14.8V
14.4V
14.2V
14.6V
13.8V
13.8V
13.8V
13.2V
13.2V
13.2V
12.6V
12.6V
12.6V
12.2V
12.2V
12.2V
12.0V
12.0V
12.0V
11.1V
11.1V
11.1V
10.6V
10.6V
10.6V
120min
——
120min
120min
120min
120min
8. Disclaimer
1) Damage through improper use or use in an unsuitable environment.
2) PV or load current, voltage or power exceed the controller's rated values.
3) Modifications or attempted repair without permission.
4) The controller is damaged due to natural elements such as lighting.
5) The controller is damaged during transportation and shipment.
6) Irreversible mechanical damage.