SPECIFICATIONS
Range
0.0 to 12.5 ppm
Resolution
0.1 ppm
±0.1 ppm ±5% of reading
Accuracy
@ 25 °C
Typical EMC Dev. ±0.1 ppm
Light Emitting Diode
Light Source
@ 525 nm
Light Detector
Silicon Photocell
Adaptation of the Standard
Methods for the Examination
of Water and Wastewater,
Method
18
edition, DPD method. The
th
reaction between iodine and
the reagent causes a pink
tint in the sample.
0 to 50°C (32 to 122 °F)
Environment
max. 95% RH non-condensing
Battery Type
1 x 1.5V AAA
Auto-Shut Off
After 2 minutes of non-use
87.5 x 63.7 x 35.2 mm
Dimensions
(3.4 x 2.5 x 1.4")
Weight
65 g (2.29 oz.)
OPTIONAL ACCESSORIES
Reagent Sets
MI527-25
Iodine powder reagent, 25 pcs.
Other Accessories
3000100
Glass cuvettes with caps (2 pcs.)
Tissue fow wiping cuvettes
3000200
(2 pcs.)
3000300
1.5V AAA batteries (4 pcs.)
CERTIFICATION
Milwaukee Instruments conform to
the CE European Directives.
Disposal of Electrical & Electronic
Equipment. Do not treat this product
as household waste. Hand it over
to the appropriate collection point
for the recycling of electrical and
electronic equipment.
Disposal of waste batteries. This product
contains batteries. Do not dispose of them with
other household waste. Hand them over to the
appropriate collection point for recycling.
Please note: proper product and battery disposal
prevents
potential
negative
for human health and the environment. For
detailed
information,
contact
household waste disposal service or go to
www.milwaukeeinstruments.com (USA & CAN)
or www.milwaukeeinst.com.
RECOMMENDATION
Before using this product, make sure it is entirely
suitable for your specific application and for the
environment in which it is used. Any modification
introduced by the user to the supplied equipment
may compromise the meter's performance. For
your and the meter's safety do not use or store
the meter in hazardous environment. To avoid
damage or burn, do not perform any measurement
in microwave ovens.
WARRANTY
This instrument is warranted against defects
in materials and manufacturing for a period of
2 years from the date of purchase. This warranty
is limited to repair or free of charge replacement if
the instrument cannot be repaired. Damage due to
accidents, misuse, tampering or lack of prescribed
maintenance is not covered by warranty. If
service is required, contact your local Milwaukee
Instruments Technical Service. If the repair is not
covered by the warranty, you will be notified of
the charges incurred. When shipping any meter,
make sure it is properly packaged for complete
protection.
ISTMW13 07/20
USER MANUAL
Mini Photometer