Application

AQUATIMER - A3000 open electronically time-controlled WC flush valve DN 20 for
in-wall installation, with facility for externally controlling options such as fitting
settings and communication via ECC function controller. For connecting to cold
water. Flushing duration adjustable down to the second.
6.

Technical Specifications

Minimum flow pressure:
Recommended flow
pressure:
Calculation flow rate:
Flushing flow:
Flush water volume:
Operating voltage:
Power consumption:
Communication:
Type of protection:
7.

Scope of Delivery

Item
Description
1
WC-flusher with solenoid valve unit
2
Electronic module M2
3
Adapter cable
4
Cover plate
5
Frame
6
Fixing set
Installation and -Operating Instructions
8.

Dimensions

9.

Installation Example

1.2 bar
1.2–4.0 bar
1.0 l/s
1.0–1.3 l/s at a flow pressure of 3 bar
6–9 l programmable
24 V DC
3.5 W
Ethernet via ECC-function controller
IP 68
5