Quest H5

1. Specifications

Part No.
4031450
Power
110-120 Vac, 2.4 amps
Blower
500 CFM
Filters:
1st stage 1"Pleated Media, 18" x 18"
(optional) 1" Carbon and Potassium Permanganate
2nd stage 2.5" Pleated HEPA 18" x 18"
Warranty
One Year, 100% Parts and Labor
Dimensions
Width
Height 14"
Depth
Weight 33 lbs.

2. Important Safety Instructions

CAUTION: Risk of electric shock. Can cause injury or death to reduce the risk of electric shock:
Do not expose to standing water or rain
Connect to GFCI outlet
Do not use an extension cord
Unplug fan before servicing or changing filters.
Do not block air intake or outlet. One foot minimum distance to obstructions.
Indoor use only
Do not use as stool or bench
Do not operate with damaged cord or plug.
Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route
cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over."

3. Operation

3.1 Transporting the Quest H5

The H5 should be transported vertically or horizontally on the appropriate feet located on the bottom of the unit or
opposite the handle.

3.2 Electrical Requirements

The Quest H5 HEPA System can be plugged into a grounded 15 Amp circuit. It draws about 2.4 Amps with clean filters
and no ducting. The amp draw will decrease slightly with added ducting and as the filters load with particulate.Due to the
presence of GFCI receptacle, the unit must be plugged directly into a wall outlet. No extension cords should be used.