Download Print this page

IHP SV4.5HTKCT Installation Instructions

Horizontal compact termination kits

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS FOR IHP HORIZONTAL COMPACT
TERMINATION KITS FOR USE WITH DIRECT-VENT GAS FIREPLACES
[Kit models SV4.5HTKCT, SV4.5HTKCT20, all SFKITXXCT, SF4.5HTKCT]
HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO
TOUCH GLASS.
• Install only when fireplace is OFF and COLD.
• Fireplace surfaces get EXTREMELY HOT!
• The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures and can cause severe
burns if touched. Even after the gas is turned off, fireplace surfaces remain extremely hot.
• Keep children away from an operating fireplace. Closely supervise children in any room where a
fireplace is operating to prevent contact with glass.
Required Tools
Safety Glasses
Protective Work Gloves
Carpenter's Level
Phillips Screwdriver
General Information
This document details installation instructions for the SV4.5HTKCT, SV4.5HTKCT20, all SFKITXXCT, and
SF4.5HTKCT horizontal compact termination kits. Information provided here supplements the instructions provided
with each fireplace and may be redundant to that information. The intent of this document is to provide complete
instructions for the aforementioned terminations, particularly any instructions exclusive to the installation of
these terminations.
These horizontal compact terminations are intended for use ONLY with the following IHP direct-vent gas fireplaces:
Aries 33", -35", -40"
DRT/DRC2033, -2035, and -2040
VeniceLightsTEN, VeniceLightsTEP
DRL4543TEN, DRL4543TEP
These terminations may not be used with other models. The terminations covered by this document seamlessly
integrate with all other components of the approved fireplaces, and when installed in accordance with the directions
provided here—and with the fireplace—constitute a complete, approved and listed installation.
C
US
P/N 900080-00
Report No. F13-94
REV. B, 04/2018
WARNING
HEARTH PRODUCTS
KITS AND ACCESSORIES
Horizontal Compact
Termination Kits

Advertisement

loading

Summary of Contents for IHP SV4.5HTKCT

  • Page 1 The intent of this document is to provide complete instructions for the aforementioned terminations, particularly any instructions exclusive to the installation of these terminations. These horizontal compact terminations are intended for use ONLY with the following IHP direct-vent gas fireplaces: • Aries 33”, -35”, -40”...
  • Page 2 Innovative Hearth Products Installation IHP Direct-Vent Gas Fireplaces 900080-00, 04/2018 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 3 Innovative Hearth Products Installation IHP Direct-Vent Gas Fireplaces 900080-00, 04/2018 Figure 1: Installing the Horizontal Termination To help minimize water infiltration it is recommended that the Firestop/Spacer (SV4.5HF) be installed on the exterior Termination side of the wall. 7” (178) 12-1/8”...
  • Page 4 WARNING Do not join separate sections of concentric flexible vent together. IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

This manual is also suitable for:

Sv4.5htkct20SfkitxxctSf4.5htkct