HP- 60/80
CAUTION
●Be sure to unplug the pump unit.
●When performing replacement work, the pump body may still be hot and you could
get burned. So please wait until the pump has cooled before handling.
●Be sure to remove the chamber block and the actuating rod before replacing the
electromagnet.
●It is better to let an experienced technician handle the soldering process. Take
precautions against getting burned.
S
S
T
T
E
E
P
P
REMOVAL OF ELECTROMAGNET
1
1
Cut the wire from terminals on the electromag-
nets with nippers.
●It is recommended that you make a note of the wiring.
S
T
E
P
S
T
E
P
2
2
Loosen the screw, fixing SP switch and remove it .
(There are hexagonal nuts at SP switch side. Be
sure not to lose them as they fall inside the unit.)
S
T
E
P
S
T
E
P
3
3
Remove the hexagonal nuts by the nut driver.
(7mm wrench)
Pull out the electromagnets from the pump body.