Download Print this page
WAREMA KNX SA 16M230 SMI REG Installation Instructions Manual

WAREMA KNX SA 16M230 SMI REG Installation Instructions Manual

Advertisement

Quick Links

Installation instructions
KNX SA 16M230 SMI REG
KNX SA 16MDC SMI LoVo REG
Keep for future use!
Valid from 1st December 2018
General information
Fig. 1
KNX SA 16M230 SMI REG /
KNX SA 16MDC SMI LoVo REG
The KNX SA 16M230 SMI REG and the
KNX SA 16MDC SMI LoVo REG sun shading actuators
are devices for the central operation of up to 16 SMI sun
shading drives in up to 16 groups.
The device is operated using a KNX bus system. The sun
shading actuator are supplied via the KNX bus. The SMI
interface is, however, operated via a
230 V AC auxiliary voltage.
The drives are directly operated with either 230 V AC or
a separate 24 V DC power supply unit with, depending
on requirements. A maximum of 16 motors without fuse
protection can be connected to the SMI interface.
Intended use
The KNX SA 16M230 SMI REG and KNX SA 16MDC
SMI LoVo REG have been developed to control SMI sun
shading products. The approval of the manufacturer must
be obtained for any use of the device other than its intend-
ed purpose specified in these instructions.
The sun shading actuator is intended for installation in
enclosed electrical operating facilities.
Safety instructions
WARNING
The electrical installation must be per-
formed by a certified electrician in accord-
ance with the electrical installation regu-
lations published by the VDE Association
for Electrical, Electronic & Information
Technologies (VDE 0100) or the standards
and legal requirements of the country in
which the device is being installed. The
electrician must observe the installation
instructions included with the electrical
devices supplied.
2024843_0•en•2018-12-01
WARNING
If hazard-free operation cannot be as-
sumed, the device may not be started or
must be deactivated. This assumption is
justified if:
 t he housing or the connecting lines show
signs of damage,
 the device is no longer working.
WARNING
It is important to comply with the fol-
lowing points in the interest of personal
safety.
Children may not play with the operating elements of
the control unit or the remote control. Store remote
controls out of reach of children.
Make sure that no persons or objects are in the path
of the driven parts (venetian blinds, external venetian
blinds, etc.).
Disconnect the device from the supply voltage if clean-
ing or other maintenance work must be performed.
Function of the sun shading actuator
You will find a detailed description of the software
functions for the KNX  sun shading actuators in the
KNX SA SMI software manual
(art. no. 2024839). You can download the manual and the
product database of the sun shading actuator from www.
warema.de/knx or from the ETS online catalogue.
Installation
The device is intended for installation in a distribution
cabinet. The device is installed by clipping it onto a DIN
rail (TH 35/DIN 60715)
Electrical connection
An on-site overload current protection device (fuse) and a
disconnecting and isolating switch to switch off the entire
system must be provided.
The electrical connection is made as shown in the wiring
diagram on the reverse side (Fig. 7), the connection to
the KNX bus system and the drives is made using spring
terminals, the connecting lines are designed as screw
terminals.
We reserve the right to make technical modifications
1

Advertisement

loading

Summary of Contents for WAREMA KNX SA 16M230 SMI REG

  • Page 1 Children may not play with the operating elements of the control unit or the remote control. Store remote Fig. 1 KNX SA 16M230 SMI REG / KNX SA 16MDC SMI LoVo REG controls out of reach of children. The KNX SA 16M230 SMI REG and the ...
  • Page 2 AppStore and in the Google Play Store. Download this to your smartphone. After starting the app, the surrounding area is scanned for WAREMA Programming sun shading actuators. Available actuators are shown and You can perform programming either in the app or directly can be operated.
  • Page 3: Led Flash Patterns

    Maintenance There are no parts inside the device that require mainte- nance. Liability Failure to comply with the product information in these in- structions and any use of the device other than its intend- ed use may result in the manufacturer refusing to honour warranty claims for product damage.
  • Page 4: Technical Data

    This device meets the EMC directives for use in residen- Fig. 6 Dimensions of 3 MW DIN rail-mounted housing for tial and commercial areas. KNX SA 16M230 SMI REG and Ambient conditions KNX SA 16MDC SMI LoVo REG. Operating temperature °C Storage temperature °C...
  • Page 5 I+ Black 1 (between BL and GNYE) Motor 15 Black 2 (between BN and GNYE) GNYE All motor lines H05RR-F 5 G 0.75 BK Type WAREMA Note: Be mindful of voltage drops across the length of the line when dimensioning the cable cross-sections! Motor 2...
  • Page 6 distributor Example: Connection of SMI LoVo motors Motor 16 Maximum of 16 motors Total power maximum 3600 VA for the power-saving relay of the SMI drives. Motor 15 Note: Be mindful of voltage drops across the length of the line when dimensioning the cable cross-sections! Motor 2 Motor 1...

This manual is also suitable for:

Knx sa 16mdc smi lovo reg