CUE irCUE 99 User Manual

Wireless ir control panels

Advertisement

Quick Links

User Manual
Wireless IR Control Panels
Version 02
CUE spol. s r.o., Na Dolinách 6, 147 00 Praha 4, Czech Republic
phone: +420 241 433 555
fax: +420 241 432 446
www.cuesystem.com
e-mail: info@cue.cz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the irCUE 99 and is the answer not in the manual?

Questions and answers

Summary of Contents for CUE irCUE 99

  • Page 1 User Manual Wireless IR Control Panels Version 02 CUE spol. s r.o., Na Dolinách 6, 147 00 Praha 4, Czech Republic phone: +420 241 433 555 fax: +420 241 432 446 www.cuesystem.com e-mail: info@cue.cz...
  • Page 2 User Manual Wireless IR Control Panels UM004_02, 27.08.2003 Copyright © CUE, spol. s r.o. Praha, Czech Republic 1990 - 2003. All rights reserved. Specifications are subject to change without prior notice.
  • Page 3: Table Of Contents

    1.4. Programming ......................... 4 Using ............................... 5 Charging ............................6 Front Panel ............................. 7 Button Labels ..........................8 5.1. irCUE 99 ..........................8 5.2. irCUE ............................. 8 Addressing ............................. 9 Receivers ............................11 7.1. irCUE Receiver........................11 7.1.1. Mounting........................11 7.1.2.
  • Page 4: Introduction

    / metal steel enclosure. The irCUE 99 is supplied in four versions of wood – mahogany, birch, white birch and oak. The irCUE 99 is designed to blend with the most critical environments. Providing 32 backlight buttons, the irCUE 99 remote control is designed to fit perfectly in your hand.
  • Page 5: Using

    2. Using The irCUE 99 and irCUE are connected to the rest of control system via IR communication with the unit irCUE Receiver or irCUE Receiver 485. The receivers then provide a connection via IR input or via CUEwire to the control units Assistant or Assistant-S.
  • Page 6: Charging

    3. Charging The irCUE 99 and irCUE wireless remote control panels are powered from internal accumulators 1 100 mAh. To charge the accumulators, use the delivered power supply adapter. The connector for connecting the charger is on the bottom side. Charging time for fully charged accumulator is 15 hours. Longer charging time is not dangerous because the protection against overcharging is built-in.
  • Page 7: Front Panel

    4. Front Panel The front panels are equipped with • Functional buttons • Backlight button • Transmit indicator The Functional buttons send IR codes to irCUE Receiver. The Backlight button activates the backlight of all buttons. The backlight lights a few seconds and after that it switches off automatically.
  • Page 8: Button Labels

    5. Button Labels 5.1. irCUE 99 ..............The panel uses one big label foil for all buttons. Steps 1. Use AutoCAD file named CS0149.0001.3-Foil.dwg for preparation of a layout. This file is available on www.cuesystem.com. The foil shape is described on the picture below.
  • Page 9: Addressing

    6. Addressing The BUTTON_ID transmitted by a panel is number used in the programming for button identification. The value depends on a button position and it depends on a panel ADDRESS too. Both values are calculated according formula BUTTON_ID = Offset + Button Code Offset = 32 * ADDRESS For addressing with irCUE Receiver 485 see chapter Receivers / irCUE Receiver 485 / Addressing.
  • Page 10 The ADDRESS of the panel can be set in the range 0 to 9 by the firmware. Standard panel has address 0, addresses 1 to 9 are delivered on a special order. In the table below there are BUTTON_ID ranges for all addresses. ADDRESS BUTTON_ID range 1025...
  • Page 11: Receivers

    7. Receivers 7.1. irCUE Receiver ............7.1.1. Mounting The ceiling near the center of the room is the best place to install it. The receiver can be mounted to the double ceiling as described on the picture below. The whole diameter is 60 mm. The minimum vertical space for the receiver is 30 mm.
  • Page 12: Connecting

    7.1.2. Connecting The irCUE Receiver can be connected to • Assistant or Assistant-S using input marked IR-REC • irCUE Receiver 485 - see connection example in the following chapter. Up to (10) receivers can be connected in parallel. Connection example is described on the pictures below.
  • Page 13: Ircue Receiver 485

    7.2. irCUE Receiver 485............. 7.2.1. Mounting The ceiling near the center of the room is the best place to install it. The receiver can be mounted to the double ceiling as described on the picture below. The whole diameter is 60 mm. The minimum vertical space for the receiver is 64 mm.
  • Page 14: Connecting

    7.2.2. Connecting Using terminals, irCUE Receiver 485 can be connected to CUEwire. CUEwire +24 V Ground +24 V Ground +12 V Address Switch Data irCUE Receiver Ground To extend the coverage, it is possible to connect up to (4) irCUE Receivers (CS0080-C) - see picture below.
  • Page 15: Addressing

    7.2.3. Addressing It is possible to add an offset to a BUTTON_ID sent by the panel using irCUE Receiver 485. It can be very helpful in multi room installation - the same panel can be identified in each room. That means one panel can start different actions in different rooms - see example on the picture below.
  • Page 16 The address of the receiver can be set up by the Address Switch - see picture above. BUTTON_ID sent by irCUE Receiver 485 to the control unit is a BUTTON_ID sent by IR wireless control panel with an added OFFSET value. Button ID and OFFSET value are calculated according formulas below. BUTTON_ID (irCUE Receiver 485) = Offset + BUTTON_ID (IR wireless control panel) Offset = 32 * ADDRESS ADDRESS is binary coded by DIP switch in the range 0 to 255.
  • Page 17: Troubleshooting

    8. Troubleshooting 1. The Brightness of LEDs is Visibly Decreasing. • Charge the accumulator immediately. 2. When pressing the button the LEDs are going on and off immediately and then back-light button flashes several times. • The accumulator is totally discharged. •...
  • Page 18: Specifications And Mechanical Drawings

    9. Specifications and Mechanical Drawings 9.1. irCUE 99 ..............Buttons layout........(32) buttons Indicator ..........Flashing during transmition Communication........IR Max. transmitting range .......25 m / 82 ft Power supply ........NiMH rechargeable battery pack Enclosure..........Wood - stainless steel panel Dimensions (WxHxD) ......215 mm (8.5”) x 70 mm (2.8”) x 33 mm (1.3”) Weight..........0.38 kg / 1 lb...
  • Page 19: Ircue

    9.2. irCUE ................Buttons..........(18) single, (7) double Indicator ..........Flashing transmitting Communication........IR Max. transmitting range .......25 m / 82 ft Power supply ........NiMH rechargeable battery pack Enclosure..........Wood - black metal panel Dimensions (WxHxD) ......210 mm (8.3”) x 83 mm (3.3”) x 22 mm (0.9”) Weight..........0.32 kg / 0.9 lb Supplied accessories......Charger, 100 - 230 VAC, 50 / 60 Hz All dimensions are in mm.
  • Page 20: Ircue Receiver

    9.3. irCUE Receiver ............Receiving ..........Horizontal level 0 - 360 degrees Vertical level ........60 degrees Connection ..........Assistant or Assistant-S IR input, screw terminals Power supply ........12 VDC, 1 W Enclosure..........Metal, plastic cover Dimensions..........Diameter 75 mm (3.0”), height 80 mm (3.2”) Weight..........0.1 kg / 0.3 lb All dimensions are in mm.
  • Page 21: Ircue Receiver 485

    9.4. irCUE Receiver 485............. Receiving ..........Horizontal level 0 - 360 degrees Vertical level ........60 degrees System connection ......CUEwire (RS-485), screw terminals Power supply ........24 VDC (+/- 20%), 1 W Enclosure..........Metal, plastic cover Dimensions..........Diameter 81 mm (3.2”), height 104 mm (4.1”) Weight..........0.1 kg / 0.3 lb All dimensions are in mm.
  • Page 22: Software And Firmware License

    License Grant CUE grants to You, as an individual, a license to install and use one (1) copy of the Software on a single computer at a time; provided, however, that You may make copies of the Software solely for Your development of applications for CUE hardware and demonstration versions of such applications.
  • Page 23: Warranty Conditions

    CUE provides warranty for all CUE products for a period of 3 years from the day of purchase. The provided warranty for touch screens is 2 years from the day of purchase. CUE accepts reclamation of 5 not properly working dots and more (2 dots join – 1 counts).
  • Page 24: Ce Declaration Of Conformity

    ST0007 Guide, CS0188 touchCUE-SRF, CS0171 rfbaseCUE, ST0013 monitorCUE-V, CS0203 monitorCUE, CS0190 touchCUE-V /i, CS0151 PC Interface 485 CS0170 rfCUE 99, CS0170 rfCUE 99, CS0149 irCUE 99, CS0133 irCUE, CS0080 irCUE Receiver, CS0169 irCUE Receiver 485, CS0221 keypadCUE-1G, CS0222 keypadCUE-2G, CS0223 keypadCUE-3G,...
  • Page 25: Fcc

    13. FCC Caution Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 26 Notes User Manual Wireless IR Control Panels www.cuesystem.com Page 26 of 26...

This manual is also suitable for:

Ircue

Table of Contents