Advertisement

Quick Links

ULTIMATE FIRE RANGER UNITS
OPERATORS HANDBOOK
400L - 2,500L CAPACITIES
Fire
Fighting

Advertisement

Table of Contents
loading

Summary of Contents for Rapid Spray FIRE RANGER

  • Page 1 ULTIMATE FIRE RANGER UNITS OPERATORS HANDBOOK 400L - 2,500L CAPACITIES Fire Fighting...
  • Page 2: Table Of Contents

    CONTENTS Statement of Suitability for Rapid Spray Diesel Tanks Introduction Warnings Product Risk Assessment Operating Instructions Before Use Operation Decontamination & Maintenance Parts Breakdown Fire Ranger 400 - 2,500L Units Poly Fire Fighting Hose Reel Bottom Fill Kit Contents Warnings...
  • Page 3: Introduction

    Rapid Spray Fire Fighting Unit Operators Handbook INTRODUCTION Congratulations on your purchase of a Rapid Spray Fire Fighting Unit which is complete and ready to slip onto a ute, truck or trailer for immediate action when you need it most.
  • Page 4: Warnings

    Rapid Spray Fire Fighting Unit Operators Handbook WARNINGS 1. When mounting to any vehicle. Ensure that you have read the Vehicle Owner’s Manual and that you comply with all weight restrictions specified by the vehicle manufacturer as overloading can cause injury or death.
  • Page 5: Product Risk Assessment

    Rapid Spray Fire Fighting Unit Operators Handbook PRODUCT RISK ASSESSMENT TASK HAZARDS RISK CONTROL MEASURES Partially fill the tank Manual handling; Medium Concentrate on task; follow safe manual with water, start the slips, trips or falls; handling techniques; don’t lift motor and test the petrol;...
  • Page 6: Operating Instructions

    Rapid Spray Fire Fighting Unit Operators Handbook OPERATING INSTRUCTIONS BEFORE USE Check all hoses, connections and hose clamps to ensure that the unit has been delivered to you without transportation loss or damage. Before attempting any fire fighting with your new unit, operate it to familiarise yourself with its features and capabilities and to ensure that your unit has arrived in a safe working condition.
  • Page 7: Decontamination & Maintenance

    Rapid Spray Fire Fighting Unit Operators Handbook DECONTAMINATION & MAINTENANCE After use the unit must be thoroughly decontaminated, inside and out, including pump, hoses and hand lance to prevent damage to the unit from corrosion or abrasion. As a guide follow the decontamination procedures below: After use, the tank, pump, hand lance/nozzle and (if required) hose should be flushed by running it with clean water plus a recommended cleaning fluid.
  • Page 8: Parts Breakdown

    Includes: 6m hose, camlock fittings and foot strainer GUARANTEED RAPID BALL BAFFLE - ARB195 / ARB355 FLUID STABILITY All Fire Ranger fire units are fitted standard withj the Rapid Ball Baffle system. MEANS SAFER OPERATION ARB195 ARB355 Small Ball Baffle Ø195mm Small Ball Baffle Ø355mm...
  • Page 9 Rapid Spray Fire Fighting Unit Operators Handbook Parts List Parts No. Description ARLP250VSR Ø250mm screw lid completed with rim & deal - suits 400 - 600L ARLP450VSR Ø450mm lid, rim and seal assembly - suits 800 - 2,500L CAP356660020NB Ø450mm lid seal only (not shown) AFHW10B036M19 36m fire fighting poly hose reel &...
  • Page 10: Poly Fire Fighting Hose Reel

    Rapid Spray Fire Fighting Unit Operators Handbook POLY FIRE FIGHTING HOSE REEL - AFHW10B036M19 Parts List Parts No. Description ASR10B Base mount frame for fire hose reel AMATH100MYE Bare hose reel CFBE25M20B 1” BSP to 20mm tail brass elbow CFSPB25M25F 1”...
  • Page 11: Bottom Fill Kit

    Rapid Spray Fire Fighting Unit Operators Handbook BOTTOM FILL KIT CONTENTS • 6m x 38mm suction hose • Camlock fittings • Foot strainer Aussie Pumps are designed for sucking water directly out of dams or water sources. The bottom fill kit is a quick, environmentally safe way of sucking up water to fill the water tank.
  • Page 12 Rapid Spray Fire Fighting Unit Operators Handbook AUSSIE FIRE CHIEF - QP205SE Rapid Spray Equipment by Rapid Spray...
  • Page 13 Rapid Spray Fire Fighting Unit Operators Handbook Parts List Parts No. Description Q4364-100010 Casing Q7304-100010 Casing with logo Q1803-100160 2" suction cover Q4725-060160-0011 1.5" suction cover Q4904-000160 2.5" suction cover Q1378-350350 Check valve Q018108-0825 Bolt set with spring washer Q019115-0525...
  • Page 14 RAPID SPRAY in addition or inconsistent with these provisions. Purchasers to whom these provisions apply agree to hold RAPID SPRAY not liable for claims by their customers in excess of the obligations of RAPID SPRAY expressly set forth herein.
  • Page 15 RAPID SPRAY, only after inspection of the failed component. In no event shall RAPID SPRAY be liable to any person for indirect or consequential damages or for injury or INABILITY | UNSUITABILITY commercial loss resulting from any use or inability to use any RAPID SPRAY product.
  • Page 16 Rapid Spray Fire Fighting Unit Operators Handbook This page has been left blank intentionally. Rapid Spray Equipment by Rapid Spray...
  • Page 17: Warranty Registration

    Hobby farm Hire company 25 - 40 Industrial Home 41 - 55 Other............... Over 55 What influenced you to purchase a Rapid Spray product? Received Catalogue Better features than competitor product Newspaper advertisement Quality & reliability Magazine advertisement Price Dealer recommendation...
  • Page 18 Call us on 1800 011 000 or visit www.rapidspray.net 35 Enterprise Cres, Singleton NSW 2330 PO BOX 3119 Singleton NSW 2330 Telephone: 1800 011 000 Facsimile: 02 6571 2951 Rapid Spray Liquid Management Systems...