[OPEN/CLOSE] Indicator

Infrared Sensor Opening Indicator

8 Troubleshooting

Alarm Types and Modes
Inside Unlocking Alarm Under Outside Forced Lock
22
The meanings of different light colors
1. With 2 flashes in red: indicates
the door is locking.
2. With 2 flashes in green: indicates
the door is unlocking.
3. With 1 flash in red: indicates
the door is deadlocking.
The meanings of different light colors
1.Fast flashing in green: Infrared sensor
opening is on.
2.Fast flashing in red: Infrared sensor
opening is off.
Triggering: If the lock is under outside
forced lock mode, unlocking from inside will
trigger the alarm.
Alarm mode: Continuously repeated alarms.
Turning off: The alarm can be turned off by
successful verification of any type.
Low Battery Voltage Alarm reminds you of replacing the batteries in time
Triggering: After waking up, the system
will run an automatic examination on the
battery voltage. If the voltage is too low, the
lock will give an alarm with a voice prompt
of "Low battery voltage. Please replace all
batteries".
Alarm mode: A voice prompt of "Low battery
voltage. Please replace all batteries" during
unlocking.
Turning off: The alarm will be automatically
turned off.
Anti-dismantling Alarm
Triggering 1: The door is pried open and the
sensor latch bolt pops up.
Alarm mode: Continuously repeated alarms.
Turning off: The alarm can be turned off
automatically or by a successful verification.
Triggering 2: The door is pried open and
there is no close fit in the door.
Alarm mode: Continuously repeated alarms.
Turning off: The alarm can be turned off
automatically, by a successful verification
from outside or normal unlocking from
inside.
Deadbolt Abnormality Alarm
Triggering: The deadbolt works abnormally,
fails to lock or unlock the door.
Alarm mode: Continuously repeated alarms.
Turning off: The alarm will be automatically
turned off.