1. Product characteristics
Passive infrared presence detector for ceiling installation
Rectangular detection area of 360°, up to
30 m x 5 m (150 m
)
2
2 separate detection zones
Restriction of detection area with cover clips
Automatic presence- and brightness-dependent control
for lighting and HVAC
Mixed light measurement suitable for fluorescent lamps
(FL/PL/ESL), halogen/incandescent lamps and LEDs
Channel A light: relay, 230 V
Fully or semi-automatic operation, switchable
Brightness setpoint adjustable, teach-in function
Reduction of time delay when present briefly (short-term
presence)
Connection option for push buttons or switches for
manual switching with automatic detection of push
button/switch
Staircase light function
Pulse function for staircase light timer switch
Channel H, presence: relay, floating e.g. for HVAC control
Switch-on delay and time delay configurable
Detection sensitivity configurable
Ready for immediate use due to factory presetting
Test mode for checking function and detection area
Extension of detection area via Master/Master switching,
a maximum of 10 detectors can be switched in parallel
with each other
Ceiling installation in flush-mounted box
Accessories: Surface mounting on ceilings possible with
back box LMS MG SURFACE MNT FRAME (B29011002),
optional; user remote control LMS MG USER REMOTE
(B29012001), optional; app remote control LMS MG
PROGRAM REMOTE BT (B29012003) optional, and the
corresponding Glamox Sensor-app (iOS/Android); safety
cover LMS SENSOR SAFETY COVER (B29011001), optional
2. Safety
WARNING
Danger of death through electric shock or fire!
Installation should only be carried out by a
¾
¾
qualified electrician!
Work on electrical systems may only be carried out by
307424
qualified electricians or by instructed persons under the
guidance and supervision of a qualified electrician in
accordance with the technical regulations applying to
electricity!
Comply with the country-specific safety regulations for
work on electrical systems! Ensure absence of voltage in
the cable before installation!
The device is maintenance-free. If the device is opened
or penetrated, the guarantee lapses.
3. Proper use
The presence detector is intended for indoor installation.
4. Function
The presence detector is primarily used in passage areas,
staircases, garages, basements and warehouses for conveni-
ent and energy-efficient control of lighting as well as HVAC.
The switch contact "light" switches lighting on with presence
and insufficient brightness, and off with absence or sufficient
brightness. The light can also be switched on/off manually
using push buttons or switches.
The "Presence" switch contact controls heating, ventilation
and air conditioning systems. The contact closes when some-
one is present, a switch-on delay permits delayed switch on.
Function description
 Mixed light measurement
 Presence detection
 Artificial light
 Push button for manual lighting control
 Incident daylight
Settings
 Brightness setpoint value (lux)
 Lighting time delay
1

Advertisement

Table of Contents
loading

Summary of Contents for Glamox B29004005

  • Page 1 LMS MG SURFACE MNT FRAME (B29011002), optional; user remote control LMS MG USER REMOTE (B29012001), optional; app remote control LMS MG PROGRAM REMOTE BT (B29012003) optional, and the corresponding Glamox Sensor-app (iOS/Android); safety   cover LMS SENSOR SAFETY COVER (B29011001), optional ...
  • Page 2: Detection Area

    5. Detection area  Presence time delay  Presence switch-on delay  Mechanical safety lock The rectangular detection area of thePassa presence detec- tor covers a large detection area, and permits a complete Channel A light coverage of the corridor. It is possible that, in certain areas, the detection area is larger than stated.
  • Page 3: Installation

    Surface-mounted installation 4.5 m 10 x 5 m (50 m 15 x 5 m (75 m 5.0 m 10 x 5 m (50 m 15 x 5 m (75 m with LMS MG SURFACE MNT FRAME (B29011002) 5.5 m 10 x 5 m (50 m 15 x 5 m (75 m 6.0 m 10 x 5 m (50 m...
  • Page 4 The specifications are guidance values. App remote control LMS MG PROGRAM REMOTE BT in combination Parameters and control commands via remote with Glamox Sensor-app is available for start-up. control It allows the remote adjustment of the setting values.
  • Page 5: Detection Zone

    Connect the app remote control LMS MG PROGRAM † ¾ Brightness setpoint A defines the minimum desired bright- REMOTE BT with the corresponding Glamox Sensor-app. ness. The currently prevailing brightness is measured under- Select the appropriate detector type <LMS MG PIR CLS †...
  • Page 6: Detection Sensitivity

    ¾ and sent to the detector. connector. Increment Sensitivity Value range (Glamox Sensor-app) very insensitive Automatic detection of push button or switch. A signal that auto insensitive is present for less than 0.7 s is detected as a push button.
  • Page 7: Factory Settings

    The motion detection can be displayed via the LED. When no one is present, the light switch contact opens ¾ after 10 s. Value range (Glamox Sensor-app) Brightness measurement deactivated, detector does ¾ not react to brightness. No display of motion detection.
  • Page 8: Troubleshooting

    Troubleshooting 11. Contact Glamox AS Fault Cause Light does not switch Lux value is set too low; detector set on semi- BU Norway on or off if presence automatic; light was switched off manually via Hoffsveien 1C is detected and in...

Table of Contents