Download Print this page

gefran KH-SIL2 Series Manual page 3

Electrical installation for pressure probes

Advertisement

RATIOMETRIC AND VOLTAGE AMPLIFIED OUTPUT
CURRENT AMPLIFIED OUTPUT – mod. E
The interface with SRP/CS (Safety Related Part of a Control System) is made by mean of multipolar connectors showed
on pictures below, where the connections are specified in case of amplified voltage output (3 wire) or current output (2
wire system, the sensor is connected in series with the current loop).
LOAD DIAGRAM
(Current output)
POWER SUPPLY VOLTAGE
RL = < (Vsupply - 10V) / 0.02A
Z - M12 x 1 (4 pin)
2 1
3 4
Protection IP67
85198A_Manual of Electrical Installation for Pressure Probes KH-SIL2-Mobyle-series_07-2019_ENG
Electrical connections
POWER SUPPLY
OUTPUT
POWER SUPPLY
SIGNAL
Interfaces with SRP/CS and voltage devices
S – AMP Superseal 1.5
Operating
Area
Protection IP67
E - EN 175301-803
Protection IP65
Red
Black
White
Red
Black
Shield
G – Deutsch DT04-4P
Protection IP67
F – 3 pole cable
White
Red
Black
Protection IP65
K – Metri-Pack 150
Protection IP67
3

Advertisement