Operating Manual for
mp6-XEVA Board
Rev. 1.0 (04.2020)

Advertisement

Table of Contents
loading

Summary of Contents for Bartels Mikrotechnik microComponents mp6-XEVA

  • Page 1: Operating Manual For Mp6-Xeva Board

    Operating Manual for mp6-XEVA Board Rev. 1.0 (04.2020)
  • Page 2: Table Of Contents

    Content Operating Manual for mp6-XEVA Board ............................... 1 General ..........................................3 Declaration of conformity..................................3 Description of functions..................................3 Proper use ........................................4 Intended purpose..................................... 4 Misuse......................................... 4 Staff selection and qualification................................ 4 About this operating manual................................4 The mp6-XEVA evaluation board ................................
  • Page 3: General

    Bartels Mikrotechnik assumes no liability for abnormal handling, improper or negligent use of the micropump and the controller that is not conform to the specified purpose of the system. This applies especially for micropump controllers, components and systems of other manufacturers, which have not been certified by Bartels Mikrotechnik.
  • Page 4: Proper Use

    Do not make any modifications or extensions to the pump or controller without the prior written consent of the manufacturer. Such modifications may impair the safety of the unit and are prohibited! Bartels Mikrotechnik GmbH rejects any responsibility for damage to the unit caused by unauthorized modifications to the pump and risk and liability are automatically transferred to the operator.
  • Page 5: Safety Notice

    Safety notice. The mp6-XEVA generates voltages of up to 250 Vpp. All parts of the mp6-XEVA evaluation board can carry voltages in this range. Therefore, the board should only be used by qualified personnel. Although the output power of the module is very low, proper insulation according to the application conditions needs to be considered by the customer.
  • Page 6: Operation

    Jumpers: JP1 – Jumper for pump frequency setting JP2 – Jumper for pump amplitude setting JP3 – Jumper for power supply setting Others: POT1 – Variable resistor for amplitude adjustment C1 – is not used with mp6-XOEM Operation. To operate a pump with the evaluation board, the following steps are necessary: Step 1: Connect the micropump of the mp6-series to the board.
  • Page 7: Pump Amplitude Setting With Jumper Jp2

    Pump amplitude setting with jumper JP2. Amplitude defined by Amplitude defined by AMPLITUDE signal at Maximal amplitude position of potentiometer Pin 4 (AMP) (250 Vpp) POT1 of screw terminal CON1 More information on the amplitude setting with the AMP signal can be found in the mp6-XOEM manual. Operation voltage setting with jumper JP3.
  • Page 8 Using the I²C-interface of the mp6-XOEM. The mp6-XOEM can be controlled via I²C when the onboard microcontroller is disabled. To do this, the reset pin of the mp6-XOEM has to be tied to GND. The trace between pins 15 and 16 of the IC-socket has to be removed on the bottom side of the board and a zero Ohm resistor (or solder joint) has to be attached to the pads next to the pins, so the reset pin (pin 15) is directly connected to the GND plane.
  • Page 9 Visit our Website Contact Data: http://www.bartels-mikrotechnik.de Bartels Mikrotechnik GmbH Konrad-Adenauer-Allee 11 for further information on applications. 44263 Dortmund Germany Tutorials and helpful answers to frequently asked http://www.bartels-mikrotechnik.de questions can be found in our FAQ info@bartels-mikrotechnik.de Tel: +49-231-47730-500 http://blog.bartels-mikrotechnik.de Fax: +49-231-47730-501 or on our YouTube channel https://www.youtube.com/user/BartelsMikrotechnik...