Adjusts the Output Horizontal Front Porch value
Parameters:
nn -
Output Horizontal Front Porch: n[Pixels]
Example:
OHFP 60
Command:
OHFQ nnnnn
Description:
Adjusts the Output Frequency value
Parameters:
nnnn -
Example:
OHFQ 48780
Command:
OHSY nn
Description:
Adjusts the Output Horizontal Sync value
Parameters:
nn -
Output Horizontal SYNC: n[Pixels]
Example:
OHSY 96
Command:
OHTT nnnn
Description:
Adjusts the Output Horizontal Total value
Parameters:
nnnn -
Example:
OHTT 1300
Command:
OINT n
Description:
Enables or disables the Output Interlaced mode
Parameters:
n -
Interlace Mode: n[0|1], NON-INTERLACED|INTERLACED
Example:
OINT 1 enables the Output Interlaced mode
Command:
OPED n
Description:
Adjusts the Output Pedestal level
Parameters:
n -
Output Pedestal; n[0-500]
Example:
OPED 10 :
Command:
ORSP op nnn
Description:
Adjusts the Output Raster Size/Position
Parameters:
op -
Select Raster Control; [H|V] Horizontal, Vertical.
nnn -
Increment/Decrement value; -999 - 999
Example:
ORSP H 100
Manual # 26-6092936-00 / Revision A
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
adjusts the Output Horizontal Front Porch value as 60
Output Horizontal Frequency: n[Hz]
adjusts the Output Horizontal Frequency to be 48,780 Hz
adjusts the Output Horizontal Sync value to be 96
Output Horizontal Total: n[Pixels]
adjusts the Output Horizontal Total value as 1300
adjusts the Output Pedestal value as 10.
increment the Horizontal Raster Size/Position by 100