AX-459 Description The AX-459 amplifier includes inside a microprocessor that digitally controls and supervises the main functions of the apparatus. This particularity, along with the universal signal input system, which can be configured by the engineer installing the system, make for a reliable, versatile and easy-to use device.
AX-459 General characteristics - Electronic protection against short-circuits in output. - Power supply suspend. - Excess temperature (110 C in the power radiator) detector. In the event of overheating caused by a ventilation obstruction, a safety device will be triggered. When temperature conditions revert to normal this devise switches off automatically.
AX-459 How to start up the unit INSTALLATION: Install the optional accessories (if applicable). See graphic. Change the sensitivity of the auxiliary input, if applicable. See graphic. The unit should be connected as per the connection diagram, according to specific requirements.
Page 6
AX-459 Change the sensibility of the auxiliary input. 250 mV 770 mV Remove the top cover of the unit. Remove the screws (A) from the rear subchassis. Move the subchassis to expose the signal input/output circuit. Connect the jumper as required.
AX-459 Connection diagram 230 VAC BASIC CONNECTION SYSTEM OPTIONAL ELEMENTS WX-19 CA-01 antilarsen module AUXILIARY AMPLIFIER CA-01 CA-32 PX-9 EG-31 PRE-AMPLIFIER EQUALIZER MICROPHONE SOUND SOURCE - Radio, CD, Cassette, etc. ATTENUATOR - 3-wires maximum level restoration 610.105A...
Page 8
AX-459 How to assemble the WX-19 module WX-19 - Remove the top cover of the unit. - Remove the bracket for the WX-19 module. - Assemble the WX-19 module in the aforementioned bracket using the screws supplied. - Fit the 6-lead connection as shown.
AX-459 Block diagram DIGITAL CONTROL 230 VAC +12 VDC 230 VAC MICROPROCESSOR +5 VDC ± 15 VDC ± 92 VDC CONTROL MATCHING DIGITAL SIGNAL 450 W RMS Th 65 C. INSERTION 0 dBm OUTPUT 610.105A...
AX-459 INSTALLER MENU The installer can use the keyboard and associated display to perform the following operations: Access the installer menu (Fig. 1) Change the password in the installer menu (Fig. 2) Select the load impedance of the unit manually (4 , 8 , 70V/16 , 100V/33 ).
Page 11
AX-459 INSTALLER MENU MICROPHONE VOLUME MANUAL Fig. 3 Fig. 5 AUXILIARY VOLUME IMPEDANCE TREBLE SELECTION BASS INPUTS E1 and E2 ADJUSTMENT MANUAL ADJUSTMENT CURRENT IMPEDANCE VALUE Z= 4 MIN. MIN. MIN. Z= 8 MAX. MAX. MAX. L= 70V L= 100V...
Page 12
AX-459 EDIT (CORRECT) AN Fig. 8 INSTALLER MENU EXISTING PROGRAMME (E.g. edit programme 7) PRESET PROGRAMME MENU RECORDING Fig. 6 PRESET CALL UP PROGRAMMES PROGRAMME PRESET TO SELECT (fig.5) PROGRAMME MENU RECOVER SETTINGS RECORDED IN PROGRAMME 7 PROGRAMME SELECTION SETTING from nº...
AX-459 Warning messages POWER SUPPLY POWER SUPPLY: If the amplifier stops working and shows the message, this means that the internal control device has switched off the unit’s power supply. This may be due to two reasons: The internal temperature of the unit is too high and the heat protector has been triggered.
Page 14
E1 or E2 Volume Value TREBLE Operating the AX-459 with remote controls TM1 and TM2. Regardless of which active input is selected (E1 or E2), when TM1 is Treble pulled E1 becomes the active input, with its corresponding volume, Value treble and bass settings.
Page 15
PROGRAMME ACTIVE INPUT E1 or E2 Operating the AX-459 with remote controls TM1 and TM2. Volume Regardless of which active input is selected (E1 or E2), when TM1 is Value pulled E1 becomes the active input, with its corresponding volume, treble and bass settings.