Download Print this page
Minitor Sfida 01 Series Operation Manual

Minitor Sfida 01 Series Operation Manual

Selector pack
Hide thumbs Also See for Sfida 01 Series:

Advertisement

Quick Links

Advertisement

loading
Need help?

Need help?

Do you have a question about the Sfida 01 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Minitor Sfida 01 Series

  • Page 2 Warning Contents ○ This device shall be grounded using the ground wire of the AC power cord. Make sure that  1. Safety Precautions        1 7. Connection of Control Pack       12    the ground wire is connected to the earth to avoid an electric shock when using this device.    In addition, confirm that the ground wire has been grounded correctly before connecting a cable   7‑1 Connection of Selector Connection Cord 2. Equipment Features       3    to this device.    7‑2 Fixing of Connecting Cord ○ If any malfunctions such as smoke, peculiar smells and/or sounds are present, turn off the main 3. Specifications and Dimensions  3   7‑3  Connection of Selector Communication Cord    switch and unplug the power supply immediately.   3‑1 Specifications    Consult an electrician for repair after confirming that all smoking has stopped. If the machine   7‑4 Connection of Spindle Connection Cord   3‑2 Dimensions of External Appearance    is damaged and used without proper repair, fire and electric shock could result.   7‑5 Connection Diagram of Entire Configuration    ○ Do not attempt to modify or disassemble the machine since this can cause serious loss in    3‑3 Accessories    performance and safety; otherwise, fire and electric shock could result. 8. Mounting of Bracket             15 4. Names and Functions of Each Component  5 ○ Be sure to only use the input voltage specified in this device since fire and electric shock 9. Replacement of operation panel     16    could result.   4‑1 Overall Configuration ○ Do not block ventilation openings since this can result in a failure or fire from heat.   9‑1  Change of Mounting Direction of Operation Panel   4‑2 Details of Operation Panel ○ Do not put Control Pack on unstable locations such as a shaky stand or a leaning surface, etc.   9‑2  Replacement of Operation Panel and Filter Panel    If it falls or topples over it can cause injury. 5. Operating Procedure       7 ○ Do not use this device under an environment where corrosive gas (chlorine gas, hydrogen sulfide,   9‑3 Cleaning of Filter   5‑1 Type of Operation Mode...
  • Page 6       (Access Channel)  (External SEL 1 Signal)    (External SEL 0 Signal) 5‑5 Setting of the function              1               OFF (0V)                  OFF (0V)  This device is able to set the following functions; e.g. Setting the maximum number  ‑1   of rotations by the motor at 60,000min  or less.              2               OFF (0V)                  ON  (12〜24V)              3               ON  (12〜24V)             OFF (0V) ○F.0 Sets restrictions on the maximum number of rotations.              4               ON  (12〜24V)             ON  (12〜24V)     Display "on"  : This restricts the maximum number of rotations. 7. When setting up the rotation direction, turn the external ROTATION signal on or off       Display "of."  : This does not restrict the maximum number of rotations.       When "on" is selected, the number of rotations by panel operation or an external    so that LED of the intended rotation direction ("CW" or "CCW") is lit. Complete the       signal can not be set at more than the preset number of rotations.    setup 100ms before turning on the external START signal. ○F.1 Sets up the maximum number of rotations(CH1).          (Rotation Direction Settings)   (External ROTATION Signal) ‑1       Display  "1〜60" kmin                          CW                          OFF (0V)       When "F.0" is in the "on" position, the preset number of rotations will be the maximum. ○F.2 Sets up the maximum number of rotations(CH2).                       CCW                         ON (12〜24V) ‑1       Display  "1〜60" kmin    8. When trying to set up the motor speed, press the "+"(up) or "−"(down) switch so        When "F.0" is in the "on" position, the preset number of rotations will be the maximum.   that the intended number of rotations is displayed in the indicator. ○F.3 Sets up the maximum number of rotations(CH3). ‑1       Display  "1〜60" kmin    9. Switch the external START signal to turn the motor on or off.       When "F.0" is in the "on" position, the preset number of rotations will be the maximum.           (Operation of motor)           (External START signal) ○F.4 Sets up the maximum number of rotations(CH4).
  • Page 8    ...
  • Page 10 10‑3 Error Numbers and Their Contents Error Number Indication Meanings 10‑1 How Error Number Is Displayed Immediately after having turned on the power supply in Remote Operation Mode, the exterior START signal will already be ON. Error was detected in the control pack. (changed to RESTART mode)  Error was detected in setting memory data of "Rotation Direction and Speed of Rotation" in the control pack. Error was detected in setting memory data of "Operation Mode" in the control pack. E. Air pressure for motor cooling is low. ‑ Indication of Error Air pressure for motor cooling is high. Abnormal motor connection. The motor can not be activated, or it took at least three seconds before reaching the preset number of rotations. Numerical value of The revolution number has been set too high on the Selector Pack. two digits Over‑current protection to the motor was activated. Protection functions of the motor power supply were activated. Transistor for the motor‑brake overheated. The display of error number is shown on the indicator with the value of two digits after "E.".  The speed of rotation does not reach number of revolutions set. Refer to "10‑3 Error Number and Their Contents" for the error number and their contents.  ‑1 The speed of rotation is low at 3000〜5000 min  or more than speed of rotation set. ‑1 Revolution of motor is high at 3000〜5000 min  or more than speed of rotation set. ‑1 Motor rotated at more than 65,000 min 10‑2 When Malfunctions Are Detected Communication between this device and Control Pack is unavailable. Immediately after having turned on the power supply in Remote Operation Mode, the exterior START signal will already be ON. When device is on and malfunctions are detected from storage data, after the previous data  Control Pack has not been set in the Selector Operation Mode,or communication with this device is unavailable. setting  (Operation  mode,  access  channel,  rotation  direction  and  rotation  speed)  is  loaded  Communication with this device is unavailable, or Control Pack has not been set in the Selector Operation Mode.

This manual is also suitable for:

Sfida mt01sp