ACCURAT Opti 5 Operating Manual page 43

Table of Contents

Advertisement

Available languages

Available languages

Specifications
Charger Type
Input Voltage
Input Power
Output Voltage
Output Current
Min. Star Voltage
Current Fuse Rating
Desulphation
Soft Start
Bulk
Absorption
Battery Test
Recondition
Float
Efficiency
Overheating Protection
Cooling Fan
Ambient Temperature
Over Voltage Protection
Deep Cycle
Battery Types
Dimensions (LxBxH)
Weight
5 (24 V)
Opti
296 W
24 V DC
5 A
4 V
250 V AC, T3,15 A
Charge Control
Pulse charge up to 11 V
Half the rated set current up to 12V
5 A up to 28,8 V
Constant voltage until
current drops to 0,75 A
Monitors voltage for 90 seconds
Constant current (0,75 A) for 4
hours limited to 32 V
27,6 V – also with pulse feature
Automatic temperature controlled
-20 °C to +50 °C, output power is reduced automatically at high
The 12V charger will automaticallyp rotection if the
Battery Range
35 – 100 Ah
Most types of lead acid batteries including Calcium, GEL and AGM
215 x 115 x 62 mm
1,2 kg
43
10 (24 V)
Opti
7 stage automatic
220 – 240 V~, 50/60 Hz
547 W
24 V DC
10 A
4 V
250 V AC, T3,15 A
10 A up to 28,8 V
Constant voltage until
current drops to 1,5 A
Constant current (1,5 A) for 4
hours limited to 32 V
approx. 85 %
65 °C +/- 5 °C
temperatures
voltage is higher than 35 V
70 – 200 Ah
215 x 115 x 62 mm
1,23 kg

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Opti 7Opti 10Opti 12Opti 15Opti 20

Table of Contents