Specifications
Charger Type
Input Voltage
Input Power
Output Voltage
Output Current
Min. Star Voltage
Current Fuse Rating
Desulphation
Soft Start
Bulk
Absorption
Battery Test
Recondition
Float
Efficiency
Overheating Protection
Cooling Fan
Ambient Temperature
Over Voltage Protection
Deep Cycle
Battery Types
Dimensions (LxBxH)
Weight
Opti 12
332 W
12 V DC
12 A
2 V
250 V AC, T3,15 A
Charge Control
Pulse charge up to 11 V
Half the rated set current up to 12V
12 A up to
14,4 V
Constant voltage until
current drops to
1,8 A
Monitors voltage for 90 seconds
Constant current (1,8
A) for 4 hours limited
to 16 V
13,8 V – also with pulse feature
Automatic temperature controlled
-20 °C to +50 °C, output power is reduced automatically at high
The 12V charger will automaticallyp rotection if the
Battery Range
80 – 240 Ah
Most types of lead acid batteries including Calcium, GEL and AGM
195 x 115 x 62 mm
1,2 kg
Opti 15
7 stage automatic
220 – 240 V~, 50/60 Hz
415 W
12 V DC
15 A
2 V
250 V AC, T3,15 A
15 A up to
14,4 V
Constant voltage until
current drops to
2,25 A
Constant current
(2,25 A) for 4 hours
limited to 16 V
approx. 85 %
65 °C +/- 5 °C
temperatures
voltage is higher than 17.5 V
100 – 300 Ah
215 x 115 x 62 mm
1,25 kg
42
Opti 20
554 W
12 V DC
20 A
2 V
250 V AC, T3,15 A
20 A up to
14,4 V
Constant voltage until
current drops to
Constant current (3,0
A) for 4 hours limited
to 16 V
134 – 400 Ah
215 x 115 x 62 mm
1,3 kg
3 A