Acquisitions X-Fire 1000 Series Installation & User's Instructions

Hide thumbs Also See for X-Fire 1000 Series:

Advertisement

Quick Links

Designer flueless fires by
INSTALLATION & USERS INSTRUCTIONS
XF-WSL LPG - Widescreen Limestone model LPG
XF-WSG LPG - Widescreen Granite model LPG
Country(s) of destination : GB, IE
Acquisitions
X-FIRES
Acquisitions X-Fires is a Registered Trade Mark
Acquisitions of London
Leave with the User
Revision D - 05/08
X-FIRE 1000
Product Codes
XF-1000L - 1000 Limestone model
XF-1000G - 1000 Granite model
XF-1000M - 1000 Mirror model
XF-1000L LPG - 1000 Limestone model LPG
XF-1000G LPG - 1000 Granite model LPG
XF-1000M LPG - 1000 Mirror model LPG
X-FIRE Widescreen
Product Codes
XF-WSL - Widescreen Limestone model
XF-WSG - Widescreen Granite model
XF-WSM - Widescreen Mirror model
XF-WSM LPG - Widescreen Mirror model LPG
Acquisitions of London
24-26 Holmes Road
London NW5 3AB UK
Tel: 24 hours 0207 482 2949
Email: sales@acquisitions.co.uk
TM
Product Identification No. 87BQ70

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X-Fire 1000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Acquisitions X-Fire 1000 Series

  • Page 1 Acquisitions X-FIRES Acquisitions X-Fires is a Registered Trade Mark Designer flueless fires by Acquisitions of London INSTALLATION & USERS INSTRUCTIONS Leave with the User Revision D - 05/08 X-FIRE 1000 Product Codes XF-1000L - 1000 Limestone model XF-1000G - 1000 Granite model...
  • Page 2 INSTALLATION INSTRUCTIONS Preliminary Notes Before Installation This appliance is a high efficiency, flueless, flame effect gas fire. It provides radiant and convected warmth both efficiently and safely utilising the latest type catalytic convertor burner technology. The appliance incorporates a combustion monitoring system (Oxygen Depletion System).
  • Page 3: Table Of Contents

    Section Contents Page No. Section Contents Page No. Important Notes Testing and Commissioning Appliance Data 8.1 Operating the Appliance Installation Requirements 8.2 Spark Failure 3.1 Room Sizing 8.3 Setting pressure Site Requirements 8.4 Fitting the Frame Assembly 4.1 Ventilation Briefing the customer Unpacking the Appliance 10.0 Servicing...
  • Page 4: Appliance Data

    APPLIANCE DATA 1000 Natural gas 1000 LPG Widescreen Natural gas Widescreen LPG G20 Natural Gas CAT I2H G31 Propane CAT I3P G20 Natural Gas CAT I2H G31 Propane CAT I3P Gas Group 20 mbar (± 2.0mbar) 37 mbar (± 2.0mbar) 20 mbar (±...
  • Page 5 SITE REQUIREMENTS (continued) installed in areas where it is likely to be exposed to persistent strong draughts, that may be generated by outside doors or windows, air vents etc. It is recommended that the appliance should not be installed within 1 metre of any air vent. Clearances to non-combustibles Non combustible surfaces are defined as brick, metal, marble, concrete etc.
  • Page 6: Ventilation

    VENTILATION A minimum of 100 cm purpose provided ventilation is required for this appliance. This may be achieved either with one vent 100 cm at a high or low position in the room, or split ventilation i.e. 50cm installed at high level and 50cm be installed at low level within the room.
  • Page 7: Preparing The Appliance

    PREPARING THE APPLIANCE X-FIRE 1000 models 1. Firstly remove the glass panel from 1. Remove the Grille. Note : X-Fire 1000 Note: This design of grille the appliance by removing the four M6 shown as example not fitted to widescreen retaining screws.
  • Page 8: Checking The Burner

    CHECKING THE BURNER There are no imitation fuel bed components to install. The appliance features a ribbon burner which is designed to produce a continuously variable band of flame over it’s length. The burner should be visually inspected to ensure it is free from any foreign matter. If it is necessary to clean or dust off the burner then the glass panel should be removed by removal of the retaining screws.
  • Page 9: Fitting The Frame Assembly

    FINAL FITTING OF THE FRAME ASSEMBLY Due to the weight of the frame assembly, it is recom- mended to seek assistance for this operation. The frame assembly will be supported by keyhole slots by four M6 screws which pro- trude from the front of the outer casing.
  • Page 10: Servicing The Burner Tray

    10.1 SERVICING THE BURNER TRAY AND GAS ASSEMBLY Firstly, remove the front facia (removal is the reverse of fitting as detailed in section 8.4), the glass panel, and disconnect the gas connection inside the appliance. The gas connections to the gas valve can now be released.
  • Page 11: Testing For Firebox Leakage

    10.3 CATALYSTS (continued) In order to calculate the combustion ratio for the appliance (CO/CO2) it is first necessary to express both gas concentrations in terms of percentage. To convert from parts per million (ppm) to a percent- age (%) divide the ppm figure by 10,000. Examples : 35ppm = 0.0035%, 15ppm = 0.0015%, 5ppm = 0.0005%.
  • Page 12: Troubleshooting Guide

    11.0 TROUBLESHOOTING GUIDE Fire sparks but pilot does not light No gas to fire, check isolators are open. Pipe work blockage, clean out. Air not fully purged, re purge supply or wait longer. Spark earthing to metal work, reset gap correctly. Blocked pilot, clean out internally.
  • Page 13 USER INSTRUCTIONS Section Content Page No Important Notes Clearances to Combustibles Ventilation & Room Size Operating Instructions Combustion Monitoring System Cleaning Servicing List of Replacement Parts IMPORTANT NOTES The installation and Servicing of this fire MUST only be carried out by a competent person (such as a CORGI registered fitter) in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards, Codes of Practice, the Building Regulations and the manufacturer's instructions.
  • Page 14 CLEARANCES TO COMBUSTIBLES Clearances to combustible materials Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Generally, any material, which is likely to discolour, melt or misshape when exposed to moder- ate heat, should be considered as a combustible material or surface. Clearance to the sides of the appliance are 100mm (4in) but curtains, drapes and other fabrics are not permitted within a distance of 500mm (20in) of the appliance sides.
  • Page 15 VENTILATION AND ROOM SIZE (continued) A supply of fresh air into the room is advisable to maintain temperatures within limits. The appliance MUST NOT be installed in a bedroom or bathroom. For Republic of Ireland, see relevant rules in force. X-Fire 1000 models : The room size should be a minimum of 30m 3 (e.g.
  • Page 16 CLEANING Before carrying out any of the following operations, ensure that the appliance is OFF and completely cold. GLASS PANEL : This can be cleaned with a suitable glass cleaner, or propriety ceramic hob cleaner. Test on a small area first. PAINTED AREAS : These can be dusted or cleaned using a dry cloth.

Table of Contents