Operating and Installation instructions
Sensor Precipitation (infrared)
Keep for future use!
Valid from 01. October 2016
General information
Fig. 1
Sensor Precipitation (infrared)
The Sensor Precipitation (infrared) is used in connection
with a downstream safety feature (e.g. sun shading control
system) to prevent damage to the sun shading system
from rain, hail or snow.
Intended use
The device was developed to control sun shading sys-
tems. The approval of the manufacturer must be obtained
for uses outside of the purposes listed in these instruc-
tions.
Safety instructions
W
WARIRG
The electrical installation must be per-
formed by a certified electrician in accord-
ance with the electrical installation regula-
tions published by the Wssociation of Ger-
man Electrical Engineers (VDE 0100) or the
standards and regulations of the country
in which the device is being installed. The
electrician must observe the installation
instructions included with the electrical
device.
W
WARIRG
The sensor may only be operated with
safety extra low voltage.
W
WARIRG
If it appears that hazard-free operation is
not possible, the device may not be started
or must be deactivated. This assumption is
justified
If the enclosure or the supply lines show
signs of damage,
If the device is no longer working.
816872_j•en•2016-10-01
W
WARIRG
Disconnect the product from the supply
voltage if cleaning or other maintenance
work must be performed!
Function
Precipitation is detected via an IR light barrier system. A
drop interrupts an IR light barrier and triggers a signal
in the downstream electronics. To prevent incorrect data
due to insects, bird droppings or fallings leaves, an "event
filter" is used. Precipitation is only indicated if at least n
drops pass the light barrier system at a certain speed
within 50 seconds of each other, where the number n is
adjustable using the encoding switch. Precipitation causes
a relay to be switched whose floating contacts can be
used to inform a connected sun shading control system
of the precipitation. An adjustable switch-off delay is used
to calm the switching signals during brief precipitation
events. The duration of the switch-off delay can also be
adjusted using the encoding switch.For extreme weather
conditions the device is equipped with heating. The heat-
ing keeps the enclosure cover at a temperature above 0
°C to prevent the accumulation of ice and snow.
Installation
The device holder is designed to be mounted on a pole.
Alternatively, it can also be mounted on a beam or wall
surface (Fig. 7). When mounting, ensure that the sensor
window is facing northward as much as possible (Fig. 7).
Electrical connection
The device is electrically connected as shown in Fig. 6.
After removing the five enclosure screws (Fig. 7), the
cover of the sensor can be removed.
R
NTIIE
Due to the use of PTCs as heating elements,
power consumption reaches a high peak
value during the switch-on phase. It must be
limited to max. 50 W by suitable measures
(e.g. power supply unit art. no. 629 054).
The device can be supplied with DC or AC
voltage.
After completing the connection work, firmly tighten the nut
of the cable gland to ensure that the inside seal encloses
the connecting lines in a watertight manner. If you are
working with a combined connecting line for heating and
power supply, leave the blind plug in the vacant gland.
Close the enclosure cover and retighten the five screws
uniformly with a torque of 1 Nm to 2 Nm to prevent water
from entering into the device. A JY(St)Y 2 x 2 x 0.8 mm
ø line can be used for the connection, although 4 x AWG
24 C UL (UV-resistant) is recommended.
We reserve the right to carry out improvements
1

Advertisement

loading

Summary of Contents for WAREMA Sensor Precipitation (infrared)

  • Page 1 Operating and Installation instructions Sensor Precipitation (infrared) Keep for future use! Valid from 01. October 2016 General information WARIRG Disconnect the product from the supply voltage if cleaning or other maintenance work must be performed! Function Precipitation is detected via an IR light barrier system. A drop interrupts an IR light barrier and triggers a signal in the downstream electronics.
  • Page 2 NTIIE Sensor lines are not permitted to be routed DIP 1 DIP 2 alongside 230 V lines to avoid the coupling of interference. Iommissioning After the device is fully mounted and the power supply is connected, the device is ready for operation. Setting the switch-off delay The switch-off delay is the time from the last measured precipitation event until the relay drops out.
  • Page 3 Degree of protection IP65 Safety class Ionnection All connections Screwed terminals Miscellaneous Conformity Viewable at www.warema.de The device meets the EMC guidelines for use in residen- tial and commercial areas. Wmbient conditions Operating temperature °C Wrticle numbers Sensor 623 045...
  • Page 4 Face the sensor 148 mm window northwards! 135 mm Standpipe mounting Enclosure- screws Aluminium, 4 mm Skintop PG 9 Blanking plug Blanking plug Wall-mounting Fig. 7 Installation instructions Fig. 5 Dimensions Sensor Precipitation (infrared) Attention! Contacts R and W are closed when de-energised, which means that precipitation will be indicated.

This manual is also suitable for:

623 045