Power Source: Wireless Unit 2x AA Ba�eries | Receiver 100 – 240VAC 50/60HZ
Frequency Band: 433 MHZ
Relay Contact: Wireless Unit 250VAC 16A | Receiver 16A or 13A op�onal.
Room temperature se�ng range: 5°C to 35°C (41°F to 90°F)
Accuracy: ±1°F or ±0.5°C
Floor temperature limita�on range op�onal: 30°C, 40°C, 55°C. Factory default: 40°C
Dimensions: Wireless Unit 115mm x 90mm x 28mm | Receiver 113mm x 82mm x 30mm
Colour: White
-
Can be placed anywhere in the home to detect and control the temperature of an area of the user's choice.
-
Link with the Receiver for a control distance of up to 100m over an open site.
-
Large LCD display.
-
The screen displays the set temperature and the room temperature and the �me simultaneously.
-
Permanent user se�ng and program se�ng reten�on in case of power loss.
-
Op�onal programming period: 7 individual days or 5 separate weekdays and 1 day/1-day Saturday and
Sunday programming with 4 or 6 �me/temperature periods per day.
-
Display temperature recalibrates
-
An�-freezing protec�on
-
Pump protec�on available.
-
Always turn off power at the main power source by unscrewing the fuse or switching the circuit breaker off
before installing, removing, cleaning or servicing this thermostat.
-
Read all the informa�on in this manual before installing.
-
Only a professional contractor should install the product.
-
All wiring must conform to local and na�onal building and electrical codes and ordinance.
-
This thermostat has a removable fuse to protect the system from damage. If the system is not opera�ng
properly, check the wiring and replace the fuse if necessary.
-
Use the thermostat only as described in this manual.
-
If the thermostat is not being used for a long �me, please remove the ba�eries to the prevent the ba�ery
fluid from poten�ally leaking.
1
01205 821 796
INSTRUCTION
MANUAL
Mul�-Click Manual
Specifica�on:
Features
Important Safety Informa�on
www.warm4less.com
office@warm4less.com

Advertisement

loading

Summary of Contents for Warm4Less MULTI-CLICK

  • Page 1 INSTRUCTION MULTI-CLICK MANUAL Mul�-Click Manual Specifica�on: Power Source: Wireless Unit 2x AA Ba�eries | Receiver 100 – 240VAC 50/60HZ Frequency Band: 433 MHZ Relay Contact: Wireless Unit 250VAC 16A | Receiver 16A or 13A op�onal. Room temperature se�ng range: 5°C to 35°C (41°F to 90°F) Accuracy: ±1°F or ±0.5°C...
  • Page 2 INSTRUCTION MULTI-CLICK MANUAL RF Address Code Se�ng and Code Match If there is another unit nearby, e.g. in the next house, your receiver may be triggered by their transmi�er. You may need to select a different RF address code by using the control centre to prevent this. The receiver can only respond to the RF coding with the same address code as its own address code.
  • Page 3 INSTRUCTION MULTI-CLICK MANUAL Installing the wireless unit Remove the 2 screws from the bo�om of the thermostat (see figure 4) and gently pull the wireless unit straight of the base. Forcing or prying the thermostat may cause damage. Push the power base into the wall.
  • Page 4 INSTRUCTION MULTI-CLICK MANUAL Power on/ an�-freezing /off bu�on Time se�ng bu�on Program se�ng bu�on Program run confirma�on bu�on Reset Bu�on Raise Temperature se�ng bu�on Lower Temperature se�ng bu�on Shows current day or days being programmed Shows current �me or �mes being programmed AM: Morning , PM: A�ernoon | Days: Nr of days , Hours: Nr of hours.
  • Page 5 INSTRUCTION MANUAL MULTI-CLICK The green LED will turn on if the hea�ng device is on. If the green LED flashes one �me it means the sensor is broken or has short circuited. Opera�on Configura�on Menu The configura�on menu allows you to set certain thermostat opera�ng characteris�cs to your system or personal requirements.
  • Page 6 INSTRUCTION MANUAL MULTI-CLICK Select °F or °C readout. Changes the display readout to cen�grade or Fahrenheit. Select fast hea�ng or slow hea�ng Select FA to start hea�ng immediately when the set point is 1°C above the room temperature. Select SL to start hea�ng only when the set point is 3°C above the room temperature.
  • Page 7 INSTRUCTION MANUAL MULTI-CLICK Momentarily press 4 shi�s between program opera�on and hold temperature opera�on. “CLOCK” shows when the thermostat is in program opera�on. Thermostat controls the hea�ng system by pre-se�ng programming. Temperature override During program opera�on, press UP or DOWN un�l the temperature you want is “FINGER UP” displayed. The thermostat will override the current programming and keep the room temperature at the selected temperature un�l the next program period begins.
  • Page 8 INSTRUCTION MANUAL MULTI-CLICK Enter hea�ng programming. Press 3 once. 1 (indica�ng Monday) will appear in the display. Also be displayed are the currently programmed start �mes for the 1 hea�ng period and the currently programmed temperature (flashing) icon indicates 1 programmed period se�ng.