Counter Value - ICP DAS USA GT-540P-3GWA-OEM2 User Manual

Intelligent 3g remote terminal unit with gps
Table of Contents

Advertisement

4.7

Counter Value

This window provides the function to inquire and modify the counter values of DI0
~ DI3. The explanation of operation and text field is below:
Text field:
(1) Name: The DI name of DI0 ~ DI3
(2) Value:The current counter value ( maximum: 999999999)
(3) Set Value: Input the defined counter value. The maximum is 999999999. This
field is enabled when DI is set as counter mode. (If users want to clear these
counter values, set 0 to these counter values.)
Operation:
(1) Read:
Read
GT-540P-3GWA-OEM2. If the DI channel is not set as counter, the counter
value is 0.
(2) Set Value : Change the counter value into GT-540P-3GWA-OEM2 according to
the "Set Value" field
When the DI channels are set as counter and data logger is enabled, the CIx field
would be added in csv files as the figure below. (x: the number of DI channel)
GT-540P-3GWA-OEM2 user's manual, Version 1.0, 2013/10
the
current
counter
GT-540P-3GWA-OEM2 user's manual v1.0
value
and
alarm
settings
from
45/53