  • Page 7 Electrical Characteristics Uses Indicating Meter—D’Arsonval, 200-microamp movement. The Type 130 is particularly useful in circuit develop- Meter Ranges—All five scales begin at zero. Full-scale ment for such uses as measuring components already in readings are 3, 10, 30, 100 and 300 microhenries or micro- place in the circuit, for sorting components , for measuring microfarads.
  • Page 8: Coarse Zero

    Specifications — Type 130 Accessories COARSE ZERO Adjustable capacitor sets the variable oscillator to the fixed-oscillator frequency P93C probe (010-003) to accommodate inclusion of the probe capacitance or other incidental capaci- W130R lead (012-015) tance. . 3-conductor power cord (161-008)
  • Page 9: Capacitance Measurement

    Connect a ground lead between so you will have am accurate zero setting when the needle the TYPE 130 and one end of the capacitance that you want is at zero and not vibrating. to measure.
  • Page 10 Operating Instructions — Type 130...
  • Page 11 FINE ZERO controls. Turn the RANGE SELECTOR to the consequence on the 0-3 μh or μμf scales. Let the Type 130 3 μμf range. Remove the first capacitor and connect the warm up for 10 to 15 minutes so it will have minimum drift 12 μμf capacitor to the instrument.
  • Page 12 Operating Instructions — Type 130 Inductance with Series Resistance Capacitance with Parallel Resistance Correction, μh Correction, μμf Series Shunt At 0 μh At 100 μH At 300 μH At 0 μμf At 100 μμf At 300 μμf Resistance Resistance 0 Ω...
  • Page 13 voltage at the UNKNOWN terminal by a small additive Variable Oscillator winding on T1. The additional voltage is just enough to V4 is the variable-oscillator tube, with T1, C2, C3, C4, C5 make up for the slight voltage loss in the cathode follower, and the unknown in the tuned circuit.
  • Page 14: Counter Circuit

    Circuit Description — Type 130 is practically symmetrical, regardless of the frequency, V15B holds the right-hand end of C90 at about +150 volts when the ADJ. 1 control is properly set. during the negative excursion while the multivibrator pulls down the left hand end to about +100 volts, thus charging The multivibrator is arranged to shift rapidly from one C90 to about 50 volts.
  • Page 15: Replacement Of Components

    C30, .001 microfarad, fixed, sign of trouble elsewhere in the circuit. The +150 volt can mica, 500 v, 1 %, part number 283-526, for Type 130 L-C be checked also at the check point indicated in Figure 5.2.
  • Page 16 If you prefer, you can order the solder directly from Tektronix in one-pound rolls. Order by Tektronix part number 251-514. Fig. 4-2. Applying iron tip to strip.
  • Page 17 Maintenance — Type 130 In soldering to metal terminals (for example, pins on a to avoid melting the plastic. A pair of log-nosed pliers tube socket) a slightly different technique should be em- (see Fig 4-6) makes a convenient tool for this purpose.
  • Page 18 They should be placed in an There are a half dozen or more insulating materials oven to dry. Compressed air is used to remove as much commonly used in rotary switches assembled in Tektronix water as practicable from the front panel area, and the instruments.
  • Page 19 Maintenance — Type 130 inner surfaces of rotor blades. When wetting the switch wafer with this contact restorer, spray surfaces until they appear wet, but not until they drip with excess fluid. Blot any excess immediately with clean soft cloth.
  • Page 21: Equipment Required

    LM-13 or Type BC-221, or a local broadcasting station with an exact harmonic of 140 kc. (4.) Low-Capacitance Calibration tools: See Figure 5.1. Fig. 5.2. Equipment needed for calibration of Type 130 L-C Meter. (b.) An accurate source of 140-kc signal is con- nected to the UNKNOWN jack.
  • Page 22 Turn the ADJ. 1 control back until the voltage rises to Set the S-30 to 0 μμf and the L-C Meter to 3 μμf. Care- midway between the two readings (i.e., around 130 volts). fully set the FINE ZERO control for zero deflection.
  • Page 23 Maintenance — Type 130 0-30 Range, ADJ. 4, R98 Set the S-30 to 30 μμf and the L-C Meter to 30 μμf. Set the ADJ. 5 control (see Figure 5-4) so that the indicating me- ter reads full scale. 10. 0-100 Range, ADJ. 4, R97 Set the S-30 to 100 μμf and the L-C Meter to 100 μμf.
  • Page 24 NOTES _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________...
  • Page 25 +3 μμfd 19 μμfd The S-30 Delta Standards provides a means for calibrat- +10 μμfd 26 μμfd ing the Type 130 L-C Meter. The accuracy of the S-30 is +30 μμfd 46 μμfd ±1% or better on all ranges. +100 μμfd 116 μμfd...
  • Page 26 S-30 Delta Standard — Type 130...
  • Page 27 2% of those shown. Connect the Type S-30, the Inductance Standardizer, and the Type 130 as shown in Fig. 6-2. Place the switch of the Type 130 in the 300 μh position. Depress the switch on the Inductance Standardizer.
  • Page 29: How To Order Parts

    HOW TO ORDER PARTS Replacement parts may be purchased at current net prices from your local Tektronix Field Office or from the factory. Most of the parts can be obtained locally. All of the structural parts, and those parts noted in the parts list “Manufactured by Tektronix”, should be...
  • Page 30 PARTS LIST ABBREVIATIONS binding head brass keps shaKEProof (nut w/- free-spinning washer) binding head steel length or long cap. capacitor met. Metal cer. Ceramic mtg hdw mounting hardware comp. Composition outside diameter conn connector oval head brass cathode-ray tube oval head screw countersunk part of double end...
  • Page 31: Mechanical Parts List

    Mounting hardware for each: (not included w/foot) 211-507 5000 SCREW, #6-32 x inch, PHS 210-006 5000 LOCKWASHER, internal, #6 210-407 5000 NUT, he., #6-32 x ¼ inch 355-014 5000 STUD, cowl fastener, #5 384-507 5000 ROD, pin PARTS LIST — TYPE 130...
  • Page 32 5001 FOOT, rubber, ½ inch - - - - - - Plate mounting hardare: (not included w/plate) 211-537 5001 SCREW, #6-32 x inch, THS (not shown) 210-457 5001 NUT, keps, #6-32 x inch (not shown) PARTS LIST — TYPE 130...
  • Page 33 ID x ½ inch OD 210-413 5000 NUT, hex., -32 x ½ inch 366-014 KNOB, small black—FINE ZERO 366-033 KNOB, small black—FINE ZERO - - - - - - Knob includes: 213-004 5000 SCREW, set, #6-32 x inch, HSS PARTS LIST — TYPE 130...
  • Page 34 (not included w/post) 358-036 5000 BUSHING, nylon, black 210-010 5000 LOCKWASHER, internal, #10 210-206 5000 LUG, solder, SE #10 210-445 5000 NUT, hex., 10-32 x 3/8 inch 211-538 5000 SCREW, #6-32 x 5/16 inch, 100º csk, FHS PARTS LIST — TYPE 130...
  • Page 35 5001 WASHER, flat, 0.390 ID x inch OD 210-413 NUT, hex., -32 x ½ inch 366-033 8749 KNOB, small black—FINE ZERO 366-148 8750 KNOB, small charcoal—FINE ZERO - - - - - - Knob includes: PARTS LIST — TYPE 130...
  • Page 36 ASSEMBLY, pilot light mounting, w/red jewel 136-079 9830 ASSEMBLY, pilot light mounting, w/green jewel - - - - - - assembly includes: - - - - - - 5168 211-538 SCREW, #6-32 x 5/16 inch, 100º csk, FHS PARTS LIST — TYPE 130...
  • Page 37 - - - - - - mounting hardware for each: (not included w/socket) 211-033 SCREW, sems, #4-40 x inch, PHS 210-004 LOCKWASHER, internal, #4 210-406 NUT, hex., 4-40 x inch 337-005 5000 SHIELD, socket, inch ID PARTS LIST — TYPE 130...
  • Page 38 210-008 5000 LOCKWASHER, internal, #8 210-409 5000 NUT, hex., 8-32 x inch 120-053 TRANSFORMER, oscillator adjustable - - - - - - mounting hardware for each: (not included w/transformer) 210-457 NUT, keps, 6-32 x inch PARTS LIST — TYPE 130...
  • Page 39 211-504 5001 5453 SCREW, #6-32 x ¼ inch, PHS 210-006 5001 LOCKWASHER, internal, #6 210-407 5001 5453 NUT, hex., 6-32 x ¼ inch 214-012 5001 5453 BOLT, spade, #6-32 x inch 354-068 5454 RING, securing PARTS LIST — TYPE 130...
  • Page 40 - - - - - - mounting hardware: (not included w/capacitor) 386-253 PLATE, capacitor flange, metal 211-534 SCREW, sems, #6-32 x inch, PHS 210-006 LOCKWASHER, external, #6 210-407 NUT, hex., 6-32 x ¼ inch 7-10 PARTS LIST — TYPE 130...
  • Page 41 - - - - - - mounting hardware for each: (not included w/strip) 210-085 5689 WASHER, flat, 0.093 ID x inch OD 210-002 5689 LOCKWASHER, external, #2 210-045 5689 NUT, hex., 2-56 x inch 7-11 PARTS LIST — TYPE 130...
  • Page 42: Cable Harness

    - - - - - - Each strip includes: 355-046 5690 STUD, plastic, clip-on - - - - - - mounting hardware for each: (not included w/strip) 361-009 5690 SPACER, plastic, 0.406 inch long 7-12 PARTS LIST — TYPE 130...
  • Page 43 - - - - - - mounting hardware: (not included w/handle) 212-004 5001 SCREW, 8-32 x imnch, PHS 381-062 5001 6213 BAR, chrome 381-159 6214 BAR, blue painted - - - - - - mounting hardware: (not included w/bar) 7-13 PARTS LIST — TYPE 130...
  • Page 44 BAR, w/2 #6-32 holes 334-0649 5001 TAG, voltage rating 117 v 50-60 c/s - - - - - - mounting hardware: (not included w/bar) 213-088 5001 SCREW, thread forming, #4 x ¼ inch, PHS 7-14 PARTS LIST — TYPE 130...
  • Page 45: Electrical Parts List

    ELECTRICAL PARTS LIST *000-000 Asterisk preceding Tektronix Part Number indicates manu- factured by or for Tektronix, also reworked or checked components. Bulb Tektronix Part Number B401 5168-up Incandescent Pilot Light 150-018 Capacitors .1 μF Fixed 400V 285-526 5-25 μμF Cer.
  • Page 46 302-470 4.7 meg ½ w Fixed Comp. 302-475 100 k Var. Comp. 311-026 82 k ½ w Fixed Comp. 302-823 47 Ω ½ w Fixed Comp. 302-470 47 Ω ½ w Fixed Comp. 302-470 7-16 PARTS LIST — TYPE 130...
  • Page 47 Primary: 117-234 vac, 60 cycles Secondary 240-0-240 vac at 40 ma 6.5 vac at 4 amp Vacuum Tubes 154-033 154-033 154-033 154-033 6BE6 154-025 154-033 6BW7A 154-028 V110 6BH6 154-026 V400 154-035 V403 154-001 7-17 PARTS LIST — TYPE 130...
  • Page 48 DIAGRAMS 7-18 DIAGRAMS — TYPE 130...
  • Page 49 Figure 7.1 Fixed Oscillator, Buffer, and Discharge Diode Figure 7.2 Variable Oscillator, Buffer, and Charge Diode 7-19 PARTS LIST — TYPE 130...
  • Page 50 Figure 7.3 Cathode Follower Figure 7.4 Mixer, Multivibrator and Clamp 7-20 PARTS LIST — TYPE 130...
  • Page 51 Figure 7.5 Range Capacitors and Power Supply 7-21 PARTS LIST — TYPE 130...
  • Page 52 TO INPUT S OCK E T SW 1-B (REAR) SW 1-A ( F RO NT ) FRONT PANEL MARKING AS VIEWED FROM REAR T YPE 130 RANGE SWITCH SHOWN IN OFF POSITION EACH DECK SHOWN AS VIEWED FROM REAR 7-22 PARTS LIST — TYPE 130...