Summary of Contents for GE Oil & Gas Masoneilan 73000 Series
Page 1
GE Oil & Gas 73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471 Instruction Manual GE Data Classification: Public...
Page 2
THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR’S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, GE (GENERAL ELECTRIC COMPANY AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED.
Useful Life Period The current estimated useful life period for the Masoneilan 73000 Series control valves is 25+ years. To maximize the useful life of the product, it is essential to conduct annual inspections, routine maintenance and ensure proper installation to avoid any unintended stresses on the product. The specific operating conditions will also impact the useful life of the product.
2. Installation Prior to installing the valve, clean the pipeline of all foreign matter such as dirt, spatters (welding chips), scale, oil or grease. Install the valve in the pipeline so that the fluid flows in the direction indicated by the flow arrows attached to the body, or the fluid flows from "IN"...
10) Tighten the nut (16) or bolt (26) of the split clamp. 11) Connect the linkage of positioner to the split clamp (18). 12) Install the body to the pipeline per installation procedures. Do not forget to install gasket between the seat ring and the body at this time.
Page 12
DIRECT SALES OFFICE LOCATIONS AUSTRALIA ITALY SOUTH AFRICA Brisbane Phone: +39-081-7892-111 Phone: +27-11-452-1550 Phone: +61-7-3001-4319 Fax: +39-081-7892-208 Fax: +27-11-452-6542 Fax: +61-7-3001-4399 JAPAN SOUTH & CENTRAL AMERICA Perth Tokyo Phone: +61-8-6595-7018 AND THE CARIBBEAN Fax: +61-8-6595-7299 Phone: +81-03-6871-9008 Phone: +55-12-2134-1201 Fax: +81-03-6890-4620 Fax: +55-12-2134-1238...