Smarteh Longo Modbus Products LMP-1.CA1M User Manual

Smarteh Longo Modbus Products LMP-1.CA1M User Manual

Card access module

Advertisement

Quick Links

USER MANUAL
Longo Modbus Products
LMP-1.CA1M
Card Access module
Version 1
SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Longo Modbus Products LMP-1.CA1M and is the answer not in the manual?

Questions and answers

Summary of Contents for Smarteh Longo Modbus Products LMP-1.CA1M

  • Page 1 USER MANUAL Longo Modbus Products LMP-1.CA1M Card Access module Version 1 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si...
  • Page 2 Longo Modbus Products LMP-1.CA1M Written by SMARTEH d.o.o. Copyright © 2020, SMARTEH d.o.o. User Manual Document Version: 1 January, 2020...
  • Page 3 24 months is valid from the date of sale to the end buyer, but not more than 36 months after delivery from Smarteh. In case of claims within warranty time, which are based on material malfunctions the producer offers free replacement. The method of return of malfunctioned module, together with description, can be arranged with our authorized representative.
  • Page 4: Table Of Contents

    Longo Modbus Products LMP-1.CA1M Longo Modbus Products LMP-1.CA1M 1 DESCRIPTION...................1 2 FEATURES..................2 3 OPERATION..................3 3.1 Modbus RTU variables..............4 4 INSTALLATION..................6 4.1 Connection scheme..............6 4.2 Mounting frame selection............8 4.3 Mounting instructions..............9 4.4 Module labeling...............10 5 TECHNICAL SPECIFICATIONS..............11 6 CHANGES ..................12 7 NOTES..................13...
  • Page 5: Description

    Longo Modbus Products LMP-1.CA1M 1 DESCRIPTION LMP-1.CA1M RFID reader is intended to be used as an identity verification device at room entrance. Module also provides display for four different messages and requests, usually activated from other module inside the room. This messages are convenient to notify personnel (e.g. occupied, do not disturb, SOS, room service).
  • Page 6: Features

    Longo Modbus Products LMP-1.CA1M 2 FEATURES Figure 1: LMP-1.CA1M module. Table 1: Features RFID reader LEDs for showing activated messages & requests: occupied, do not disturb, room service, SOS OK “ √ ” LED FAULT “ X ” LED Power LED...
  • Page 7: Operation

    Longo Modbus Products LMP-1.CA1M 3 OPERATION Operation of the CA1M module is also dependent on parameters received on Modbus RTU communication channel. Reader RFID field is active always when module is powered up. If tag is put inside RFID field, reader tries to resolve RFID tag code.
  • Page 8: Modbus Rtu Variables

    Longo Modbus Products LMP-1.CA1M 3.1 Modbus RTU variables Do not use poll times smaller than 200 ms and greater than 4 s. Table 2: 4xxxx, Holding registers Raw → Engineering data Reg. Name Description Save EEPROM settings; change oSaveModbusSettings the value from 0 to 12345 to...
  • Page 9 Longo Modbus Products LMP-1.CA1M Table 4: 0xxxx, Coils Raw → Engineering data Reg. Name Description → Disable beep when new ID is Enabled oIDNewBeepDis → detected Disabled → Reset oBuzz Set/Reset Buzzer → → Fault not confirmed oIDCodeFault ID code Fault confirm →...
  • Page 10: Installation

    Longo Modbus Products LMP-1.CA1M 4 INSTALLATION 4.1 Connection scheme Figure 2: Connection scheme...
  • Page 11 Longo Modbus Products LMP-1.CA1M Table 6: K1 K1.1 N.C. Not connected K1.2 Ground K1.3 7 .. 30 V DC Power supply input K1.4 Standard RS-485 A Data receive/send line A K1.5 Standard RS-485 B Data receive/send line B K1.6 N.C.
  • Page 12: Mounting Frame Selection

    Master ● Frames of other vendors most probably suits as well, but they were not verified by Smarteh. Before installation verify compatibility of non listed frames. Module housing has a fin on each side, which can be easily removed with knife cutter or pliers. This adaptation enables housing to be build in various frame formats with two different depths.
  • Page 13: Mounting Instructions

    Longo Modbus Products LMP-1.CA1M 4.3 Mounting instructions Figure 4: Housing dimensions Dimensions in millimeters. All connections, module attachments and assembling must be done while module is not connected to the main power supply. Module should not be mounted outdoors. Several RFID panels should not be mounted close to each other. Minimum distance to next panel is at least 30 cm.
  • Page 14: Module Labeling

    EEE – version code (reserved for future HW and/or SW firmware upgrades). ▪ 3. S/N: SSS-RR-YYXXXXXXXXX - serial number. SSS – short product name, ◦ RR – user code (test procedure, e.g. Smarteh person xxx), ◦ YY – year, ◦ XXXXXXXXX– current stack number.
  • Page 15: Technical Specifications

    Longo Modbus Products LMP-1.CA1M 5 TECHNICAL SPECIFICATIONS Table 9: Technical specifications Power supply from main module RJ-12 6/6, 4/6 Interconnection connector type Power consumption RFID type ISO/IEC 14443 A/MIFARE Max. reading distance 4 cm Dimensions (W x H x D)
  • Page 16: Changes

    Longo Modbus Products LMP-1.CA1M 6 CHANGES The following table describes all the changes to the document. Date Description 10.01.2020 The initial version, issued as LMP-1.CA1M module UserManual.
  • Page 17: Notes

    Longo Modbus Products LMP-1.CA1M 7 NOTES...