5. Connect Fixtures Together
Install the jumper cables between the mounted fixtures. The 1FT jumper (WPX-JMP1) may be looped for
minimum distance between fixtures. Longer cables may be sleeved through PVC, EMT, or wiremold if desired.
Figure 5.1: Fixture Jumper
6. Attach the End Cap
Ensure the last fixture in every daisy chain is capped. Each leader cable is packaged with an end cap.
Failure to cap the fixture will result in water ingress.
7. Connect the Leader Cable and Power Supply
Depending on the distance between the power supply and the first fixture, the leader cable may have to be
extended with proper gauge of wire. Please see table 3.2.
(White)
(Black)
Figure 7.1 and 7.2: Leader Cable Dimensions and Wiring
Brown or Black (Line)
Blue or White (Neutral)
Green (Ground)
Figure 7.3: Standard Power Supply Connection
STRONG.
Power Supply
Red
(+48VDC)
Black
(Common)
SIMPLE.
Red
(+48VDC)
All Connections Occur in Box
Black
(Common)
COMPACT.
Light Fixture(s)