2. Verify Electrical Plan & Power Supply Load
Verify the fixture layout, power supply and maximum load, using the tables below.
Power Supply
WPX-PSU-600 (600W)
WPX-PSU-480 (480W)
WPX-PSU-320 (320W)
WPX-PSU-240 (240W)
WPX-PSU-120 (120W)
WPX-PSU-80 (80W)
Length & Output
WPX8 - SO
WPX6 - SO
WPX4 - SO
WPX2 - SO
WPX8 - HO
WPX6 - HO
WPX4 - HO
WPX2 - HO
WPX8 - SHO
WPX4 - SHO
Table 2.1: Power Supply Specifications
Load/Run Length
1-3 Lights (4A)
4-6 Lights (8A)
7-9 Lights (12A)
Table 2.2: Wire Gauge Table
In some installations, the leader cable must be extended to reach from the fixtures to the power supply. The wire
gauge required will depend on the load and the run length (see above). This will limit the voltage drop to ~3V.
STRONG.
Enclosure
IP67 (Indoor/Outdoor)
IP67 (Indoor/Outdoor)
IP67 (Indoor/Outdoor)
IP67 (Indoor/Outdoor)
IP67 (Indoor/Outdoor)
IP67 (Indoor/Outdoor)
Fixture
Fixtures Supported per Power Supply
Watts
PSU-80
PSU-120
50 W
1
2
37 W
2
3
25 W
3
4
12 W
6
8
80 W
0
1
60 W
1
1
40 W
1
2
20 W
3
4
115 W
0
1
58 W
1
2
1-50 Feet
50-100 Feet
16AWG
14AWG
14AWG
12AWG
12AWG
10AWG
SIMPLE.
Max Load
Input Voltage
Standard Output (SO)
120-277VAC
80 Feet
120-277VAC
64 Feet
120-277VAC
40 Feet
120-277VAC
32 Feet
120-277VAC
16 Feet
120-277VAC
12 Feet
PSU-240
PSU-320
4
5
6
7
8
10
14
20
2
3
3
4
5
7
9
13
1
2
3
5
100-150 Feet
12AWG
10AWG
8AWG
COMPACT.
Max Load
High Output (HO/Color)
48 Feet
40 Feet
28 Feet
20 Feet
8 Feet
6 Feet
PSU-480
PSU-600
8
10
9
10
13
15
22
22
5
6
7
8
9
9
16
16
3
4
7
8
Rev Date 19 0815