Summary of Contents for Netafim NETAJET 4G

  • Page 1 NETAJET ™ USER MANUAL V 002.01 - DECEMBER 2020...
  • Page 2: Use Of Symbols

    TAKES THE GREATEST POSSIBLE CARE IN DESIGNING AND PRODUCING BOTH ITS PRODUCTS AND THE ASSOCIATED DOCUMENTATION, THEY MAY STILL INCLUDE FAULTS. ™ NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL. ™ NETAFIM RESERVES THE RIGHT TO MAKE CHANGES AND IMPROVEMENTS TO ITS PRODUCTS AND/OR THE ASSOCIATED DOCUMENTATION WITHOUT PRIOR NOTICE.
  • Page 3: Table Of Contents

    3. Calibration of the NetaJet™ 4G while irrigating List of parts BP PL mode BP ST mode High-flow mode Octa - 8-channel mode IL PL mode IL ST mode Dosing channels Venturis Dosing boosters Netajet 4g hydraulic condition checklist Warranty...
  • Page 4: Safety

    SAFETY CAUTION Read the safety instructions before using, maintaining or troubleshooting the NetaJet™ 4G. Safety instructions • All safety regulations must be applied. • Ensure that the installation is carried out in a manner that prevents leaks from the NetaJet™ 4G, the fertilizer/acid tanks and lines, the peripherals and the accessories (contaminating the environment, soil or ambient area).
  • Page 5: When Using Acid/Chemicals

    Immediately after each injection of any of the fertilizer combinations above, flush the NetaJet™ 4G with clean water for at least 2 minutes. In case of doubt regarding the use of any combination of fertilizers, contact your local Netafim™ representative.
  • Page 6: Description

    DESCRIPTION Features • The NetaJet™ 4G realizes Netafim’s “grow more with less” concept. Based on Netafim’s unique Nutrigation™ technology, it controls the amount of water and fertilizers used, optimizing resource utilization for each specific crop and soil/substrate type. • The NetaJet™ 4G is extremely accurate and reliable, preventing water and fertilizer waste while reducing environmental pollution.
  • Page 7: Analog Dosing Channel

    DESCRIPTION Analog dosing channel The NetaJet™ 4G is the first fertilizer-dosing system equipped with Netafim's unique innovative analog dosing channel. The analog dosing channel is the long-awaited solution for very accurate and reliable EC/pH control for Nutrigation™ of high-value greenhouse crops.
  • Page 8: Capabilities

    • High pressure: 5.8 - 7.5 bar (84.0 - 108.5 PSI) For main line pressures lower than 2.5 bar (36.5 PSI), consult Netafim™. NetaJet™ 4G modes fed by a storage tank The water level in the storage tank should not be higher than 5 meters (16.4 feet) above the NetaJet™ 4G inlet.
  • Page 9: Modes

    DESCRIPTION Modes • BP PL: Bypass system for pressurized-line water source; 5 dosing channels (see page • BP ST: Bypass system for storage-tank water source; 5 dosing channels (see page • High-flow: High-flow bypass system for pressurized-line water source; 5 dosing channels (see page Octa - 8-channel: Bypass system for pressurized-line water source;...
  • Page 10: Bp Pl Mode

    Standard: 2.5-5.8 bar (36.5-84.0 PSI) • High pressure: 5.8-7.5 bar (84.0-108.5 PSI) For main line pressures lower than 2.5 bar (36.5 PSI), consult Netafim™. Dosing channels: Accommodates a wide variety of highly accurate dosing channels for fertilizer and concentrated/diluted acid: •...
  • Page 11 DESCRIPTION BP PL mode - typical setup NetaJet™ 4G Schematic diagram Legend Dosing channel Scope of delivery Direction of flow Main part list on page 9 4G USER MANUAL 11 NETAJET ™...
  • Page 12: Bp St Mode

    Optional - Concentrated acid channel, 50 l/h (13 GPH) Total fertilizer/acid suction capacity - up to 3000 l/h (792 GPH). Controller: NMC-Pro (Operation with third-party controllers is optional. Consult Netafim™.) EC/pH: Precise single or dual monitoring and control - selectable by customer.
  • Page 13 DESCRIPTION BP ST mode - typical setup NetaJet™ 4G Schematic diagram Legend Dosing channel Scope of delivery Direction of flow Main part list on page 9 4G USER MANUAL 13 NETAJET ™...
  • Page 14: High-Flow Mode

    Optional - Concentrated acid channel, 50 l/h (13 GPH) Total fertilizer/acid suction capacity - up to 5000 l/h (1320 GPH). Controller: NMC-Pro (Operation with third-party controllers is optional. Consult Netafim™.) EC/pH: Precise single or dual monitoring and control - selectable by customer.
  • Page 15 DESCRIPTION High-flow mode - typical setup NetaJet™ 4G Schematic diagram Legend Dosing channel Scope of delivery Direction of flow Main part list on page 9 4G USER MANUAL 15 NETAJET ™...
  • Page 16: Octa - 8-Channel Mode

    The Octa mode (8 dosing channels) includes 3 dual dosing channels. There are fertilizer combinations that should never be used in any concentration in the dual dosing channel! (see CAUTION, page 5) Controller: NMC-Pro (Operation with third-party controllers is optional. Consult Netafim™.) EC/pH: Precise single or dual monitoring and control - selectable by customer.
  • Page 17 DESCRIPTION Octa - 8-channel mode - typical setup NetaJet™ 4G Schematic diagram Legend Dosing channel Dual dosing channel (see page Scope of delivery Direction of flow Main part list on page 9 4G USER MANUAL 17 NETAJET ™...
  • Page 18: Il Pl Mode

    Optional - Concentrated acid channel, 50 l/h (13 GPH) Total fertilizer/acid suction capacity - up to 2000 l/h (528 GPH). Controller: NMC-Pro (Operation with third-party controllers is optional. Consult Netafim™.) EC/pH: Precise single or dual monitoring and control - selectable by customer.
  • Page 19 DESCRIPTION IL PL mode - typical setup NetaJet™ 4G Schematic diagram Legend Dosing channel Scope of delivery Direction of flow Main part list on page 9 4G USER MANUAL 19 NETAJET ™...
  • Page 20: Il St Mode

    Optional - Concentrated acid channel, 50 l/h (13 GPH) Total fertilizer/acid suction capacity - up to 2000 l/h (528 GPH). Controller: NMC-Pro (Operation with third-party controllers is optional. Consult Netafim™.) EC/pH: Precise single or dual monitoring and control - selectable by customer.
  • Page 21 DESCRIPTION IL ST mode - typical setup NetaJet™ 4G Schematic diagram Legend Dosing channel Scope of delivery Direction of flow Main part list on page 9 4G USER MANUAL 21 NETAJET ™...
  • Page 22: Operation And Maintenance

    OPERATION AND MAINTENANCE Operation The routine operation of the NetaJet™ 4G is almost totally automatic, controlled by the controller (for the operation of the controller, see the enclosed Controller Manual). All you need is to make sure that: • Electricity is supplied to the NetaJet™ 4G. •...
  • Page 23: Maintenance

    OPERATION AND MAINTENANCE Maintenance CAUTION When opening or closing any manual valve, always do so gradually, to prevent damage to the system by water hammer. To prevent failures and extend the life cycle of the NetaJet™ 4G, the user must carry out regular maintenance.
  • Page 24: Winterization

    OPERATION AND MAINTENANCE Winterization CAUTION When opening or closing any manual valve, always do so gradually, to prevent damage to the system by water hammer. In areas susceptible to freezing temperatures, if the system is not required for irrigation during the winter, perform the following procedure to avoid damage caused by freezing when the NetaJet™...
  • Page 25: Troubleshooting

    The controller settings regarding the irrigation valves are correct (see the enclosed Controller Manual). Perform the actions in their order of appearance until the malfunction is fixed. If you identify faulty parts - consult your Netafim™ representative. CAUTION Only qualified electricians are permitted to perform electrical installations and repairs!
  • Page 26: Symptoms Regarding A Single Dosing Channel

    If it is clogged - it should be dismantled and thoroughly cleaned (see the enclosed Dosing Booster Manual). If after implementing all the above steps the malfunction is still not fixed - consult your Netafim™ representative. Symptoms regarding a single dosing channel...
  • Page 27 (see the enclosed Controller Manual). A "click" should be heard from the dosing valve with each toggle - if a "click" is not heard, replace the dosing valve (consult your Netafim™ representative). If a "click" is heard and the dosing valve...
  • Page 28: Symptoms While Idle

    (internal deformation). If internal deformation is present - replace the Venturi (consult your Netafim™ representative). If after implementing all the above steps the malfunction is still not fixed - consult your Netafim™ representative. Symptoms while idle If the following symptoms occur while the NetaJet™ 4G is idle, perform the actions listed below: Controller warnings •...
  • Page 29: The Netajet™ 4G Does Not Function At All

    10) If the malfunction is still not fixed - replace the dosing valve. If after implementing all the above steps the malfunction is still not fixed - consult your Netafim™ representative. The NetaJet™ 4G does not function at all...
  • Page 30: Dosing Calibration

    DOSING CALIBRATION The process of calibrating the NetaJet™ 4G dosing channels is carried out in three stages: 1. Calculation of dosing channel opening percentage To finely calibrate the NetaJet™ 4G dosing channels in order to achieve homogeneous and stable dosing, perform the following calculation for each dosing channel (fertilizers and acids) to determine the amount of suction reduction needed to attain the required fertilizer/acid flow rate.
  • Page 31 DOSING CALIBRATION Note the required dosing ratio of each fertilizer solution and the dosing ratio of the acid solution (if used). Fill a bucket with 10 liters (2 US gallons) of the client's supply water (without fertilizer or acid). Measure the EC and the pH levels of the water in the bucket using calibrated portable sensors. EXAMPLE Supply water (without fertilizer or acid) 0.3 Using a measuring tube or a syringe, take a dose from each fertilizer solution and from the acid solution (if...
  • Page 32: Calibration Of The Netajet™ 4G While Irrigating

    DOSING CALIBRATION With the controller set to operate according to EC/pH values - if the EC and pH values measured in the bucket are within a range of ±30% deviation from the target values, the system will be able to correct them automatically.
  • Page 33 DOSING CALIBRATION If the EC and pH target values cannot be attained, and the dosing valves are opened more than 85%, measures should be taken to increase the dosing ratio - if feasible, slightly increase the concentration of the fertilizer solution and/or reduce the water flow rate to the field during irrigation. If not - consult the agronomist/consultant.
  • Page 34: List Of Parts

    LIST OF PARTS BP PL mode Main parts for all modes table, pages 40-41 34 NETAJET 4G USER MANUAL ™...
  • Page 35: Bp St Mode

    LIST OF PARTS BP ST mode Main parts for all modes table, pages 40-41 4G USER MANUAL 35 NETAJET ™...
  • Page 36: High-Flow Mode

    LIST OF PARTS High-flow mode Main parts for all modes table, pages 40-41 36 NETAJET 4G USER MANUAL ™...
  • Page 37: Octa - 8-Channel Mode

    LIST OF PARTS Octa - 8-channel mode Main parts for all modes table, pages 40-41 4G USER MANUAL 37 NETAJET ™...
  • Page 38: Il Pl Mode

    LIST OF PARTS IL PL mode Main parts for all modes table, pages 40-41 38 NETAJET 4G USER MANUAL ™...
  • Page 39: Il St Mode

    LIST OF PARTS IL ST mode Main parts for all modes table, pages 40-41 4G USER MANUAL 39 NETAJET ™...
  • Page 40 LIST OF PARTS Main parts for all modes Part Description Cat. No. Aluminum frame for BP PL, BP ST, IL PL, IL ST Not availabe as spare part Aluminum frame for High-flow, Octa Not availabe as spare part Control unit Per NetaJet™...
  • Page 41 Inlet flange, 63 mm for IL ST with CRI 15 / CRI 20 pump 33152-002210 * To order spare parts, call your local Netafim™ local representative with the serial number of your NetaJet™ 4G at hand. Only with this number we can supply the correct part for your specific NetaJet™ 4G.
  • Page 42: Dosing Channels

    LIST OF PARTS Dosing channels Description Analog Analog Analog Analog Digital Up to 50 l/hr Up to 150 l/hr Up to 400 l/hr Up to 600 l/hr Up to 1000 l/hr (13 GPH) (39.5 GPH) (105.5 GPH) (158.5 GPH) (264 GPH) with manual with manual with manual...
  • Page 43: Venturis

    LIST OF PARTS Dosing channel parts Part Description Cat. No. Check valve, connecting between analog EPDM dosing valve and Venturi with EPDM 76420-007965 4.01 Check valve, connecting between analog Viton dosing valve and Venturi with Viton 76420-007960 4.02 Check valve, connecting between S22 digital dosing valve and Venturi with EPDM ISO 76420-007950 Analog EPDM dosing valve 70800-001795...
  • Page 44: Dosing Boosters

    Mode (kW) (kW) Cat. No. CRI 5-7 BP/IL PL 2.35 7,70-6,35/4,45-3,70 77800-003050 CRI 5-11 BP/IL PL 3.15 10,8-9,35/6,20-5,40 Call Netafim™ CRI 10-5 Octa / IL ST 3.15 10,8-9,35/6,20-5,40 77800-027420 3 x 220-277 Octa, high 13,6-11,8/ CRI 10-6 4.15 77800-027405 pressure...
  • Page 45: Netajet 4G Hydraulic Condition Checklist

    NETAJET 4G HYDRAULIC CONDITION CHECKLIST Check the inlet, lower manifold, outlet and main line Serial number pressure gauges and the main line flow meter and make Project name sure all the hydraulic conditions are in range according Technician name to the following table.
  • Page 46: Warranty

    If the installation was not reported or was reported later than 30 days from the date of installation, Netafim™ will warrant the NetaJet™ 4G for a period of 18 months from the date of production, according to its serial number.