Rebar detector and covermeter; additional memory function
Hide thumbs Also See for profoscope:

Advertisement

Additional Memory Function of the Profoscope
Select memory card symbol to activate the data storage
mode.
Minimum cover function is automatically deactivated if the
memory function is turned on.
Two different memory functions are supported:
Manual: After locating, cover value and rebar diameter can
be stored by the operator.
Auto: Used for surface scans. Every time a rebar is de-
tected, the cover value is stored automatically.
After selecting the memory function, the status line on the measuring screen is modified:
Object number
Measurement number
It is recommended to set up a separate object for each structural element (e.g. column, wall). Every
measuring position on this object can then be assigned to a measurement number.
Manual Storage Mode:
Automatic Storage Mode:
Rebar diameter is not stored in the automatic mode.
+
Manual Storage Mode
Automatic Storage Mode
Memory card missing or defective
(max.500)
(max.99)
Estimate diameter and store values
Delete last measurement
Open next object
Start / Stop automatic storage
(
blinking while recording)
Delete last object
Open next object
Quick Reference Guide to the ProfoLink
Installation
Locate the file „Profolink_Setup" on your computer or the CD and follow the installation wizard.
Open the battery compartment and connect the Profoscope
on the Profoscope
screen, the connection is established properly.
+
1
6
4
5
3
2
1. Download objects from the Profoscope
2. Expand object to see details
3. Measurement number
4. Cover value
Data Management and File structure:
Profoscope
+
Measurements
Objects (*.csv)
(max.99)
(max.500)
+
to the USB port. If the icon
7
8
5. Rebar diameter
+
6. Add object name
7. Switch between regional settings or units
8. Add comments
Select the menu "delete all objects" to delete all
data stored on Profoscope
. This will delete all
+
objects and cannot be undone.
"Add" function synchronizes data between PC
and Profoscope
. In addition, locally stored data
+
files can be added to an existing project.
PC / ProfoLink
Projects (*.pqs)
Objects (*.csv)
appears