Fitting The Stability Bracket; Connecting To Gas - Zanussi GAS COOKER ZCG 640 Instruction Booklet

Zanussi cooktop user manual
Table of Contents

Advertisement

FO 0179
Fig. 2

Fitting the Stability Bracket

(Not supplied)
If the cooker has to be installed with a flexible supply
pipe, it is necessary that a stability device is fitted.
(See "Important Safety Requirements").
The stability bracket is to be fitted by the installer and
these instructions should be read in conjunction with
the leaflet packed with the stability bracket.
Place the cooker in its intended position and level
cooker.
Mark off 295mm (11
/
") from the right hand side of the
1
2
cooker as shown, this is the centre line of the bracket
fixing.
Draw a line 100mm (4") from the front edge of the
levelling feet (see Fig. 2) and remove cooker from its
position. Mark off 480mm (19") back from this line on
the centre line of the bracket to locate the front edge of
the lower bracket.
Fix lower bracket (with two fixing holes) to the floor, then
measure height from floor level to engagement edge on
back of cooker, dimension 'A' of Fig. 2.
Assemble upper bracket to lower bracket so that
underside of bracket is dimension 'A' +3mm (1/8") above
floor level. Re-position cooker and check that top
bracket engages into cooker back to a depth of 75mm
(3"), as shown in Fig. 2.
Should the stability bracket currently installed not allow
the cooker to stand correctly, ask the installer to replace
it with the correct type.
16

Connecting to Gas

This cooker is designed to be installed with an appliance
flexible connection. Connection is made to the RC 1/2
(1/2" B.S.P.) threaded entry pipe located just below the
hotplate level on the rear right-hand side of the cooker.
Check for gas soundness after connecting the gas
supply.
The gas bayonet connector must be fitted in the shaded
area indicated in the diagram. Take into account that it
must be possible to pull the cooker forward sufficiently.
The hose must not get caught on the stability bracket.
Note:
For certain types of gas bayonet connection used, it
may not be possible for the appliance to be pushed fully
back to the wall stops.
Important:
Flexible tubing MUST comply with BS.669 Current
Edition.
600
FO 0180
450
130
Fig. 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zcg 641

Table of Contents